My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 12:52:19 PM
Creation date
6/3/2020 9:48:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />A- PTPING SUMP TESTING <br />Test Method Developed By. [3 Sump Manufacturer 0 Industry Standard 0 Professional Engineer <br />[I Other (Sj)ecift) <br />Test Method Used: L3 Pressure ❑ Vacuum N Hydrostatic <br />❑ Other (SPect&) <br />Test Equipment Used: Incon Sump Tester =Equipment Resolution: 0.002" <br />�7 <br />STP Sump 91 <br />Sump Diameter.- <br />48" <br />Sump Depth: <br />54" <br />Sump Material: <br />Fiberglass <br />I [eight from Tank Top to Top of <br />Highest Piping Penetration: <br />1V <br />Height from Tank Top to Lowest <br />Liectrical Penetration: <br />6' <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />2" above piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?' <br />El Yes 0 No 0 NA <br />Turbine shutdown response time <br />N/A <br />Is system programmed for fail-safe <br />shutdown'?* <br />[I Yes E] No 1@ NA <br />Was fail-safe verified to be <br />operational?* <br />E] Yes [-] No to NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />Test Start Time: <br />6:17 pm <br />Initial Reading (Rj): <br />4.9629 <br />Test End Time: <br />6:32 pin <br />Final Reading (RF): <br />4.9633 <br />Test Duration: <br />15 mill. <br />Change in Reading (R,; -R[): <br />+0.0004 <br />Pass/FailThreshold or Criteria: <br />+/- 0.002" <br />Test Result: <br />Z Pass Fail <br />Was sensor removed for testing? <br />IR Yes El No 0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />E Yes [] No [] NA <br />Comments — (include information on repairs made prior to lesling. and recommended fallow -up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the <br />Secondary Containment testing- scope of work". <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to anv of the question,, indicated with an <br />asterisk (*) is "NO" or "NA". the entire sump must be tested, (See SWRCB [.G-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.