Laserfiche WebLink
MONITORING SYSTEM CERTIFIC TION <br />e By All Jurisdictions Within the State of Califomi <br />Authority Cited: Chapter 6.7, and Safety Code; Chapter 76, Division 3 Title 23, MWrnia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or retort must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: SHELL # 136186 <br />Site Address: 3725 TRACY BLVD <br />Facility Contact Person: MANAGER <br />Make/Model of Monitoring System:SIMPLICITYH <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: TRACY <br />Contact Phone No: 835-7608 <br />Date of Testing/Service: 03/14/2007 <br />Work Order Number: 2247869 <br />CA Zip: 95376 <br />Tank ID: 1-87-1 <br />Tank ID: 2-87-2 <br />%( In -Tank Gauging Probe. <br />Model: MAG 1 <br />z In -Tank Gauging Probe. <br />Model: MAG 1 <br />X Annular Space or Vault Sensor. <br />Model: 301 <br />Z Annular Space or Vault Sensor. <br />Model: 301 <br />X Piping Sump/Trench Sensor(s). <br />Model: 352 <br />Piping Sump/Trench Sensor(s). <br />Model: 352 <br />X Fill Sump Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: 208 <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: PLLD <br />Electronic Line Leak Detector. <br />Model: PLLD <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: 3-91 <br />Tank ID: - <br />71 In -Tank Gauging Probe. <br />Model: MAG 1 <br />71In-Tank Gauging Probe. <br />Model: MAG 1 <br />X Annular Space or Vault Sensor. <br />Model: 301 <br />N Annular Space or Vault Sensor. <br />Model: 301 <br />X Piping Sump/Trench Sensor(s). <br />Model: 352 <br />X Piping Sump/Trench Sensor(s). <br />Model: 352 <br />X Fill Sump Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />-xl Electronic Line Leak Detector. <br />Model: PLLD <br />71 Electronic Line Leak Detector. <br />Model: PLLD <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />ispenser : 1/2 <br />Dispenser ID: 3/4 <br />3q Dispenser Containment Sensor(s) <br />Model: BEAUDREAU <br />X Dispenser Containment Sensor(s) <br />Model: BEAUDREAU <br />® Shear Valve(s). <br />X Shear Valves) <br />E] Dispenser Containment Float(s) and Chain(s). <br />7 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8,9/10 <br />X❑ Dispenser Containment Sensor(s) <br />Model: BEAUDREAU <br />X Dispenser Containment Sensor(s). <br />Model: BEAUDREAU <br />X� Shear Valve(s). <br />N Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />71 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 11/12,13/4 <br />Dispenser ID: 15/16 <br />X❑ Dispenser Containment Sensor(s) <br />Model: BEAUDREAU <br />71 Dispenser Containment Sensor(s). <br />Model: BEAUDREAU <br />FX Shear Valve(s).X <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />* If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): R System set-up X❑ Alarm history report <br />Technician Name (print): ROBERT SANTOS <br />Certification No.: 5254122 -UT <br />Signature: <br />License. No. <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 03/14/2007 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />