COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 12:52:19 PM
Creation date
6/3/2020 9:48:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�F <br /> Veeder-Root " <br /> .�t3 <br /> In-Station Diagnostics (ISD) , <br /> Monitoring is the key to successful vapor <br /> recovery compliance. <br /> Veeder-Root's California Air Resources Board <br /> (CARB) certified In-Station Diagnostic (ISD) ISD can be added to any TIS-350 <br /> equipment is designed to monitor the collection allowing you to leverage your <br /> and containment of vapors by vapor recovery investment and centralize moni- <br /> equipment. Using the existing Veeder-Root TLS- toring and recording activities. <br /> 350/EMC platform, probes and Dispenser <br /> Interface Module (DIM) cards, the ISD software <br /> continuously monitors the vapor recovery equip- <br /> ment, maintains test records, provides test Air quality IS an issue <br /> reports,and generates warnings/alarms follow- <br /> ing equipment failures. NVMEM 2 Board - (Non-Volatile Memory) One <br /> per TLS,provides memory expansion necessary for ISD that effects millions of <br /> The ISD system includes the following new com- report storage <br /> ponents: Americans every day. r <br /> As of the September 1st, 2005 implementation date, ISD <br /> • Vapor Flow Meter (Sensor) - One per systems are required for new and rebuild stations in CA Veeder-Roots ISD °'^ <br /> dispenser,designed to measure the volume of that dispense more then 1.8 million gallons / year. The <br /> vapors collected during vehicle refueling for implementation date for new and rebuild stations dispens- system monitors <br /> vapor collection monitoring ing more then 600 million gallons/year is April 2006.For <br /> • Vapor Pressure Sensor - One per station, both throughputs, existing stations must retrofit an ISD 04dous emissions <br /> designed to continuously measure contain- system within four years from the implementation date. <br /> ment tank pressures for leakage and over- <br /> For details as well as to view the CARB Executive Order <br /> pressure conditions for vapor containment requiring Enhanced Vapor Recovery(EVR)and In-Station th iQ air r <br /> Diagnostics (ISD) see the CARB website at { <br /> monitoring g <br /> • ISD Software Enhancement Module (SEM) - http://www.arb.ca.gov/vapor/eos/eo-vr202/eo-vr2O2a.htni. <br /> One per TLS,activates ISD software <br /> technology <br /> Benefits of the Veeder-Root EVR/ISD system: <br /> CARB certified to meet Enhanced Vapor Recovery(EVR)Sa'In-Station Diagnostics(ISD) <br /> requirements <br /> _+ Alarms when there is a vapor collection problem on a hose <br /> Alarms when the vapor space is leaking <br /> ' Can be added to existing TLS-350 console system <br /> Sensors are able to share wiring conduit with other Veeder-Root intrinsically safe(IS)sensors <br /> l 6 +f • Interfaces to the existing Smart Sensor Interface Module(either the 7 input or 8 <br /> input version) <br /> • Simple installation,compatible with all dispensers <br /> • Underwriters Laboratories(UL)listed <br /> • Continuous monitoring of the vapor recovery system including notification if the systems <br /> performance drops below required level <br /> Archive the reports required to meet California regulations <br /> The ISD system monitors gasoline vapors from the delivery • Reduction in emissions related to failed or degrading equipment <br /> tanker to the tank of a car to ensure that the vapor recovery Leverages existing TLS-350 equipment <br /> equipment is operating properly and the air remains clear. <br /> �� VEEDER-ROOT <br />