Laserfiche WebLink
FA0003780 PR0231417 SCO01 01/25/2017 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 6 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.or,/g ehd <br />4iE7"I =- a ia'il ii 4 .: <br />i+G:,i,�, <br />EN <br />r ,,fi } + 'x 1( r, = i ue;-'xir. - r4 , �,. �I `ih - ,x moi: - x s1 , 5i ,z ;., ( <br />.ft ...., >..'. <br />.x _ '-`�' _ ' <br />i+ii t <br />��i�i nai <br />'�`'.'i ii� �'F7,i�i7IFiilil <br />loll) d; s'r •ir' <br />(H <br />M— <br />L�Gritl u���yl�. r aua z - <br />Facility Name: <br />Facility Phone: <br />Date: <br />TRACY SHELL* <br />(209) 835-7608 <br />1 <br />January 25, 2017 <br />Facility Address: <br />CERS ID: <br />3725 N TRACY BLVD, TRACY, CA 95376 <br />10181411 <br />Inspection Contact: <br />Title: <br />Phone: <br />Tanya Moore <br />Manager <br />(209) 835-7608 <br />Inspection Type: <br />Program: <br />ROUTINE INSPECTION <br />- Operating Permit <br />2361 - UST FACILITY <br />Consent For: <br />Consent Given By: <br />® Inspection ® Photos ® Sample <br />Tanya Moore, Manager <br />Service Technician Onsite: <br />Exp. Date: <br />Designated Operator: <br />Exp. Date: <br />Kristopher Bell <br />08/24/2018 <br />Kristopher Bell <br />11/30/2017 <br />Service Technician Manufacturer's Training <br />Veeder root, 05/11/17; VMI, 11/11/18 <br />CCR=California Codeo egu a ions HSC=Health and Safety Code CFR = Codeo a era Regulations <br />V = Violation R =Repeat violation COS = Corrected on site during inspection <br />- <br />a`tih ;,. ;" ":.. �__w....._l 5 l .)+r� <br />- k�il,, <br />:'F„„'%, 5 �a <br />25 h (0 F9'; "tir <br />'n;... �y �..-.,lw.�r.. <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V ❑ R <br />❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V ❑ R <br />❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />■ V ■ R <br />❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />❑ V ❑ R <br />❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />■ V ❑ R <br />❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />■ V ❑ R <br />❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V ❑ R <br />❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V ❑ R <br />❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V ❑ R <br />❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V ❑ R <br />❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V ❑ R <br />❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V ❑ R <br />❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V ❑ R <br />❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V ❑ R <br />❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V ❑ R <br />❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V ❑ R <br />❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V ❑ R <br />❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V ❑ R <br />❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V ❑ R <br />❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V ❑ R <br />❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />■ V ❑ R <br />❑ COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />❑ V ❑ R <br />❑ COS <br />y .. ., r?".' <br /># ; <br />211-1 M <br />mm2 <br />�x '._.l, 11,1115111 <br />Failed to maintain alarm logs and/or records of follow up actions <br />■ V ■ R <br />❑ COS <br />201 <br />CCR 2712(b) <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />❑ V ❑ R <br />❑ COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />❑ V ❑ R <br />❑ COS <br />FA0003780 PR0231417 SCO01 01/25/2017 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 6 Underground Storage Tank Program OIR <br />