6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professi,°' 1. Engine � <br />❑ Other (Specify) ; x .'-, , ;- <br />,, <br />Test Method Used: ❑ Pressure ❑ Vacuum to Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Sump Diameter: <br />STP Sump # 87 <br />STP Sump # 89 <br />STP Sump # 91 <br />STP Sump # Diesel <br />42" <br />42" <br />42" <br />42" <br />Sump Depth: <br />59" <br />63" <br />59" <br />63" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />12" <br />13" <br />13" <br />16" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />9" <br />9" <br />8" <br />9" <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water ?" <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No U NA <br />❑ Yes ❑ No U NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?` <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No U NA <br />❑ Yes ❑ No U NA <br />Was fail-safe verified to be <br />o erational?° <br />❑ Yes ❑ No U NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No U NA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />12:31 pm <br />12:31 pm <br />12:01 pm <br />12:01 pm <br />Initial Reading (RI): <br />5.6639 <br />3.6515 <br />2.2584 <br />3.2181 <br />Test End Time: <br />12:46 pm <br />12:47 pm <br />12:16 pm <br />12:16 pm <br />Final Reading (RF): <br />5.6630 <br />3.6515 <br />2.2583 <br />3.2180 <br />Test Duration: <br />15 min. <br />16 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -R,): <br />0.0009 <br />None <br />0.0001 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/-0.00211 <br />+/-0.00211 <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />D Pass ❑ Fail <br />© Pass ❑ Fail <br />rx-1 Pass ❑ Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes [I No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />N Yes ❑ No E]NA <br />® Yes [INo [INA <br />® Yes [INo [INA <br />® Yes ❑ No [INA <br />_Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />t If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />