My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2024 12:59:25 PM
Creation date
6/3/2020 9:48:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F_ -11 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />TRACY SHELL" <br />3725 N TRACY BLVD, TRACY <br />January 27, 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. The monitoring system alarm <br />panel test log was incomplete. These records shall be maintained on site for at least three years. Monitoring <br />records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br />maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br />field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br />(6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br />monitoring records for the last three years on site and submit copies to the EHD. <br />This is a minor violation. <br />310 <br />CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product. <br />The diesel STP sump sensor failed to activate an audible and visual alarm when tested to ensure continuous <br />monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm <br />or stop the flow of product at the dispenser when it detects a leak. The sensor was replaced and retested during the <br />inspection. This was corrected on site. <br />During testing of the diesel STP, the turbine would not shut off. The service technician replaced the diesel product <br />turbine relay. This was corrected on site. <br />This was corrected on site. <br />This is a minor violation. <br />314 <br />CCR 2631(a) Primary containment not tight (pre -Jul 2003). <br />Approximately one gallon of liquid was found in the 91 product fill sump, indicating a leak in the primary piping. All <br />primary containment for the UST system must be tight. Immediately have a properly licensed, trained, and certified <br />contractor repair or replace the failed component under permit and inspection of the EHD. <br />Seepage or leakage at or above the shear valve in dispensers 1/2 for 87, 89, and 91 products, 3/4 for 91 product, <br />5/6 for 91 product, 7/8 for 87 and 91 products, 9/10 for 87, 89, and 91 products, and 11/12 for 87 product were <br />detected during the inspection. The service technicians were able to correct the seepage in some dispensers; <br />however, dispensers 1/2 still has seepage for 87, 89 and 91 products, 3/4 still has seepage at 91 product, 7/8 still <br />has seepage at 91 product, and 11/12 still has seepage ate 87 product. Immediately have a properly licensed, <br />trained, and certified contractor repair or replace the failed component under permit and inspection of the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />On site on January 27, 2016, to conduct a routine UST monitoring system certification, spill container, and line <br />leak detector inspection. A Return to Compliance Certification form and inspection report were left at the site at <br />the time of the inspection. Tanya Moore, manager, gave permission to perform the inspection, take photos, and <br />collect samples, if needed. <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial): <br />VICKI MCCARTNEY, Senior REHS <br />(209) 468-9852 <br />01/27/2016 <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.