Laserfiche WebLink
Monitoring System Certification - Page 2 of 3 <br />Site Address: 3725 N. Tracy Blvd. Date of Testing/Servicing: 1129/13 <br />D. Results of Testing / Servicing <br />Software Version Installed— 127.04 <br />Comnlete the Wining rht-eklict- <br />01 Yes <br />❑ No* <br />Is the audible alarm operational? <br />0 Yes <br />❑ No* <br />Is the visual alarm operational? <br />® Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />09 Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />® N/A <br />operational? <br />® Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) IM Sump/Trench Sensors; 11 Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? n Yes ❑ No <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />Do N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill oint(s) and operating properly? If so, at what percent of tank ca achy does the alarm trigger? 0 % <br />® Yes* <br />❑ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />® Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ® Water. If yes, describe causes in Section E, below. <br />® Yes <br />❑ No* <br />Was monitoring system set-up reviewed to ensure Eroper settings? Attach set-yre orts i a licable. <br />IM Yes <br />❑ No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />- in aecrion E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: Replaced 91 STP Sump Sensor (794380-208' - Re -tested & Passed with Inspector. <br />Removed approx 1/4 cup of liquid from 91 Fill Sump. <br />Monitor Certification perfomed as Annual Certification & for Permit Final due to replacement of <br />87 Product Relay on 1/19/13. <br />