Laserfiche WebLink
sSTATE Of CAUfORNiA <br /> STATE WATER RESOURCES CONTROL BOAR11 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM 8 <br /> COMPLETE A SEPARATE FORM FOR H TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED 0 <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 6 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: az <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS– SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.0.9 / 8. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/OAY/YEAR) / 0. TANK CAPACITY IN GALLONS: <br /> 11.TANK CWENTS IFA-I IS MARKED.COMPLETE ITEM C. (j 6 AVIATION GAS <br /> 3 DIESEL <br /> I8 REGULAR <br /> � ❑ <br /> A 1? 1 MOTOR VEHICLE FUEL 4 OIL 8. C. `—J <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ lb PREMIUM 4 GASAHOL ❑ 7 METHANOL <br /> UNLEADED 5 JET FUEL <br /> 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE Q 2 LEADED PI99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.x <br /> Ill. TANK CO NSTRU ION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (V LTED TANK) ❑ 99 OTHER <br /> ❑ <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE �❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> I RUBBER LINED ❑ 2 ALKYD LINING =.;96 <br /> 3 XY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR (� 5 GLASS LINING ❑ 6 UNLINED C 95 UNKNOWN ❑ 99 OTHER <br /> LINING u <br /> IS LINING MATERIAL COMPATIBLE WITH 1001:METHANOL? YES_ NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP = 2 COATING = <br /> 3 VI L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ,=_f 5 CATHODIC PROTECTION = 91 NONE ❑ 5 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A 09 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> S. CONSTRUCTION A©1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W1 COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A UA GALVANIZED STEEL A V 10 CATHODIC ROTECTICN A UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION t AUTOMATIC UNE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 9 MONITORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> F71 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING F74 AUTOMATIC TANK GAUGING C__ 5 GROUND WATER MONITORING <br /> TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> Vi.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF I 3.WAS TANK FILLED WITH YES —' NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? U ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANT'S NAME DATE <br /> (PRINTED d SIGNATURE <br /> 12-12-3 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW I97 <br /> COUNTY# JURISDICTION It FACILITY# TANK* <br /> STATE I.D.; j� p <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE 2 ` <br /> i / <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORMA HAS BEEN FILED.c���✓J,�n , <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS U <br /> FORM 3 (12.91) FOR RWi <br />