My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2003-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:22:04 AM
Creation date
6/3/2020 9:49:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2009
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2003-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Quik Stop #124 <br />Site Address: 505 N. Main St. <br />Facility Contact Person: Michael Karyelot <br />Make/Model of Monitoring System: Gilbarco EMC <br />B. Inventory of Equipment Tested/Certified <br />('hnrli tho nnnrnnrinto hnroc to indirnto cnorit7r —ain—t incnortod/corvirrd- <br />City: Manteca <br />Bldg. No.: <br />Zip: 95336 <br />Contact Phone No.: ( 510 ) 657-8500 <br />Date of Testing/Servicing: 6 /27 /05 <br />Tank ID: 89 <br />Tank ID: 87 <br />■ In -Tank Gauging Probe. <br />Model: Mag Probe <br />■ In -Tank Gauging Probe. <br />Model: Mag Probe <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794360-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: Vaporless LD -2000 <br />■ Mechanical Line Leak Detector. <br />Model: Red Jacket Fx1V <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />■ Tank Overfill / High -Level Sensor. <br />Model: oPW 61 so-EVR <br />0 Tank Overfill / High -Level Sensor. <br />Model: oPW 61 s0-EVR <br />❑ Other (specify equipment ty e and model in Section E on Pae 2). <br />❑ Other(specify equipment a and model in Section E on Pae 2). <br />Tank ID: 91 <br />Tank ID: <br />■ In -Tank Gauging Probe. <br />Model: Mag Probe <br />❑ In -Tank Gauging Probe. <br />Model: <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: FE Petro STP -MLD <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />■ Tank Overfill / High -Level Sensor. <br />Model: oPW 61 so-EVR <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment a and model in Section Eon Page 2). <br />❑ Other (specify equipment a and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />■ Shear Valve(s). <br />■ Dis enser Containment Float(s) and Chain(s). <br />1 0 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ❑Q System set-up FAjl9rm history report <br />Technician Name (print): Phillip Kingman Signature: - - <br />Certification No.: 006-05-0809 <br />License. No.: 617238 <br />Testing Company Name: Walton Engineering Inc. Phone Noj- 916 ) 373-1152 <br />Site Address: 3900 Commerce Drive, West Sacramento, CA 95691 Date of Testing/Servicing: 6 / 27 /_05 <br />UN -036 - 1/4 Page I of 3 Rev. 06/04/01 <br />COPA: San Joaquin County Env. Health <br />INSPECTOR: Ray Von Flue <br />ALTON <br />"ENGINEERING, INC. <br />www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.