My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2003-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:22:04 AM
Creation date
6/3/2020 9:49:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2009
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2003-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL SILL CONTAINER TEE* REPORT <br /> TEST DATE: June 4, 2009 <br /> Al. FACILITY A2. OWNER <br /> Name Quik Stop Market#124 Name Quik Stop Markets, Inc. <br /> Address 505 N.Main Street,Manteca,CA 95336 Address 4567 Enterprise Street, Fremont,CA 94538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 <br /> Contact Michael Karvelot Contact Michael Karvelot <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E. Main Street,Stockton,CA 95202 Address P.O. Box 1025,W.Sacramento,CA 95691 <br /> Notified May 27,2009 Lic# 617238 A,B,Haz <br /> Inspector Thuy Tran Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Caldwell System 2001 /Walton Engineering (Level Change Indicator) <br /> Tank Number 1 2 3 <br /> Product contained Gasoline-87 Gasoline-89 Gasoline-91 <br /> Spill container capacity (US gallons) 5 5 5 <br /> Spill container manufacturer OPW OPW OPW <br /> Spill container depth (inches) 15.25 15.25 13.50 <br /> Is the spill container located in a sump? Yes Yes Yes <br /> Does sump have a liquid sensor installed? No No No <br /> Condition of spill container prior to testing Wet Dry Wet <br /> Portion of spill container tested Entire Entire Entire <br /> Depth of water level from bottom (inches) 13.75 13.75 12.00 <br /> Wait time for water level to stabilize (hr:min) 0:10 0:10 0:10 <br /> Test start time 11:05 10:30 9:55 <br /> Test end time 11:15 11:00 10:25 <br /> Test duration (hr:min) 0:10 0:30 0:30 <br /> Change in water level (t 0.000 inches) 0.125 0.000 0.000 <br /> Pass/Fail threshold (0.005 inches/1/2 Hr.) 0.005 0.005 1 0.005 <br /> TEST RESULT FAIL PASS PASS <br /> L. COMMENTS: <br /> Replaced the swivel adaptor and fill cap on the 91 fill. <br /> Replaced the fill cap on the 89 fill. <br /> WALTON <br /> Signature: — ENGINEERING,INC. <br /> Technician: Bruce N.Stewart/A31131 5249892-UT Date: June 4, 2009 <br /> ©2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.