My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2003-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:22:04 AM
Creation date
6/3/2020 9:49:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2009
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2003-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />D. Results of Testing/Servicing <br />Software Version Installed: 6b(, <br />Coinplete the following cherklict! <br />Yws <br />❑ No* <br />Is the audible alarm o rational? <br />❑ No* <br />Is the visual alarm operational? <br />Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their Eo er operation? <br />❑ Yes <br />❑ * <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />LJ/N/A <br />operational? <br />es <br />❑ No* <br />❑ N/A <br />dary containment <br />For pressurized piping systems, does the turbine omatically shut down if the pi/Coainment <br />Y pe y <br />monitoringsystem detects a leak, fails too opera or �s electrical) disconnected? Ih sensors initiate <br />positive shut -down? (Check all that apply) Sump/Trench Sensors; ❑ Dispenser Sensors. <br />Did ou confirm ositive shut -down due to leaks and sensor failure/disconnection? No. <br />❑ Yes <br />❑ N <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill oint(s) and o ratin ro erl ? If so, at what rcent of tank capacity does the alarm trigger? % <br />❑ Yes* <br />No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; ❑ Water. If yes, describe causes in Section E, below. <br />Ye <br />❑ No* <br />Was monitoring system set-up reviewed to ensure Ero22r settings? Attach set up reports, if applicable <br />0,1fes <br />❑ No* <br />Is all monitorin ui mento erational 2er manufacturer's specifications? <br />ue aecuon r, oelow, aescrtne now and when these deficiencies were or will be corrected. <br />E. Continents: <br />Page 2 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.