My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sugov.org/ehd <br />nd7,7 ll round Storage Tank P m it -,l� i �� otion Report <br />ility Address: Date: <br />Facility Name: T505 <br />QUIK STOP MARKET #5124 N MAIN ST, MANTECA June 16, 2016 <br />UST System Observations' <br />326 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V o R o COS <br />327 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V o R o COS <br />329 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V o R ❑ COS <br />"1 ��Pressurized,Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V o R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />o V o R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V o R o COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIGN <br />(CLASS 1, CLASS U, or MINOR 4041ce to Comply) <br />Item # <br />Remarks <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 91 STP sump (approximately 1/2 cup) and in the 89 fill sump (8 gallons). If water could <br />enter into the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br />The service technician removed all liquid from above sumps and placed it in the onsite hazardous waste container. <br />Ensure that all sumps and annular spaces are maintained free of liquid. This was corrected onsite. <br />This is a Class II violation. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 89 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br />a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it passed. This <br />was corrected on site. <br />This is a repeat violation, Class II. <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The 89 and 91 spill containers failed when tested. All spill containers shall have a minimum capacity of five gallons <br />and be capable of containing a spill or overfill until it is detected or cleaned up. New fill caps were installed on both <br />spill containers and these spill containers were retested during the inspection with passing results. This was corrected <br />onsite. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Page 3of4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.