505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #5124" <br />505 N MAIN ST MANTECA <br />June 18 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />319 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 87 -octane fill sump. If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. The service technician removed 7 -gallons of liquid from the <br />87 -octane fill sump. Ensure that all sumps and annular spaces are maintained free of liquid. This was corrected on <br />site. <br />This is a Class II violation. <br />323 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 89 -octane line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A <br />"UST Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br />contractor. This was corrected on site. <br />This is a Class II violation. <br />325 <br />CCR 2635(b) Spill container failed to contain a minimum Capacity of five gallons. <br />The 89 -octane spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and <br />be capable of containing a spill or overfill until it is detected or cleaned up. The technician replaced the spill container <br />drain valve and retested the container with passing results. This was corrected on site. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by July 18, 2015. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received By <br />Received By (printed name and title): <br />Franchise <br />Date: <br />is— <br />(signature): <br />Satwinder Singh, owner <br />O s— <br />Inspector <br />Inspector <br />Inspector (printed name and title): <br />Inspector Phone: <br />(signature): <br />ELENA MANZO, REHS <br />(209) 953-7699 <br />\-/ 0 <br />Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.