My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Quik Stop #124 Facility 505 N. Main St., Manteca inspection Jun 29, 2012 <br />Name: p Address: Date: <br />VIOLATIONS <br /># <br />I C1 <br />I C2 <br />M <br />I Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />1 <br />1 CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M7) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION & MONITORING SYSTEM CERTIFICATION <br />Class II violation: (313) <br />313. The 91 spill container failed when tested. All spill containers shall have a minimum capacity of five <br />gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately <br />discontinue deposition of petroleum into this tank until the component is repaired or replaced by a <br />properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the spill <br />container can't be replaced immediately, there is a possibility that the 91 UST system may be red tagged <br />to prevent fuel inputs. REPEAT VIOLATION <br />Notice to Comply - Minor violations: (310, 311) <br />310. Liquid was observed in the 91 STP sump (approximately 1 liter), 91 fill sump (31 liters), and the 87 <br />fill sump (64 liters). If water could enter into the secondary containment by precipitation or infiltration, it <br />must be removed and disposed of properly. This liquid was removed by the technician at the time of <br />inspection. Ensure that the sumps are maintained free of liquid. <br />311. The 89 line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak <br />detector, retested it, and it passed. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD by July 29, 2012 <br />along with a statement documenting the corrective actions that have been or will be taken for each <br />violation and any supporting paperwork. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />7Z-Kwh,Aj- i <br />EHD 23-02 Rev /1 12 Page 3 I CIJ/ Z 1(� � UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.