My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2022 10:40:57 AM
Creation date
6/3/2020 9:49:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #5124*
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231442_505 N MAIN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
snxironmen��Heo�hDepa�mont <br /> SHAUN <br /> � � � � �U � <br /> ���0n�����U � <br /> �... .��~~=�~~ " "" <br /> --COUNTY-- <br /> AdIPM <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#5124* 505 N MAIN ST, MANTECA June 13, 2018 <br /> -A louk <br /> ply <br /> Item# Remarks <br /> 206 CCR 2712 Failure to comply with LIST operating permit conditions. <br /> A copy of the LIST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> The area manager was able to get a copy of the permit to operate email to the store to correct this violation on site. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 87 product, 89 product and 91 product annular sensor was found not located at the bottom of the tank to detect <br /> a leak at the earliest opportunity. The wrap around sensor for the 87 product was calculated to be 3 inches longer <br /> from the calculated location.The 89 product was calculated to be 48 inches longer than the calculated location. The <br /> 91 product was calculated to be 52 inches longer than the calculated location. Monitoring equipment shall be <br /> maintained to be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the lowest <br /> point of the tank by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at <br /> the earliest opportunity. <br /> This was corrected on site. <br /> This is a Class 11 violation. <br /> 309 CCR 2636(fl(l)Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain in the 87 product in UDC 1/2 sump failed to stop the flow of product at the dispenser <br /> when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br /> of product at the dispenser when it detects a leak. The service technician adjusted the chain and verified <br /> This was corrected on site. <br /> This is a repeat violation, Class 11. <br /> 318 CCR 2636(0(2)Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 89 grade VMl line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> This was corrected on site. <br /> This is a repeat violation, Class 11. <br /> r^0006*1 pn0231+42 SCO01 06m3/2018 <br /> s*o,`o, n"".1013112017 Page*mo Underground Storage Tank Program om <br /> 1868 E Hazelton Avenue| Stockmn, California 95205| T 209468'3420| r 209 464-0138 1 vmmw.sjuehd.onm <br />
The URL can be used to link to this page
Your browser does not support the video tag.