u <br />n <br />11.4. INTERNAL ELECTRICAL WIRING (continued) <br />(a) The mother board provides six wiring posts for audio and visual alarms, and the alarm cir- <br />cuits functional test switches which are located on the front cover alarm panel. The interface <br />between the mother board and the channel PC card is accomplished with a 15 contact cardedge <br />connector. Next to each PC cardconnector are three male quick connects marked (BLUE, <br />WHITE,RED). These are provided for the connections between the mother board and the zener <br />safety barriers. Located at the top of the mother board to the left are the connections for the <br />relay contacts. And on the left side on the board are the power supply connections to the mother <br />board. The only field replaceable wiring is that connection between the mother board and the <br />zener safety barrier. No attempt should be made to repair, replace, or modify any otherwiring on <br />the mother board. <br />(b) Base plate wiring consists of the input power connection, relay output connection and <br />ground bar connections. The input power connector is marked (INPUT POWER 115 VAC, LINE <br />NEUT, GRD, and RELAYCONTACTS RATED FOR 115 VAC 5 AMPS, COM, NO, NC); these repre- <br />sent input powerof 115 volts ac connecting the line to the LINE terminal, neutral to the NEUT. ter- <br />minal and ground to the GRD terminal. The relay contacts are rated for 115 volts ac at 5 amperes, <br />the arm of the relay is marked COM, the normal open contact is marked NO, and the normal <br />closed contact is marked NC. Mounted on the base plate are the DC power supply, mother <br />board, input power connector, zener safety barrier support bracket and ground bar. These parts <br />and wiring are all factory installed and can not be repaired or modified in the field. <br />(c) Mounted on the front cover alarm panel are a red visual alarm indicator, an audio alarm and <br />it's silence switch, one liquid alarm test button, and one vapor alarm test button. The visual and <br />audio alarm can be triggered with any alarm signal generated from any of the sensing channels. <br />The audio alarm can be silenced with the alarm silence switch without effecting the visual alarm <br />or function of the system. The source of the alarm can be identified by viewing the individual PC <br />channel cards LED indicators. The LIQUID and VAPOR test switches are used for functional <br />tests on active liquid and vaporchannels. The lamp in the red visual alarm may be replaced in the <br />field. There are no other replaceable, repairable parts or wiring on the front cover. <br />(For information on wiring and installation see Section Ill., page 15 FIELD INSTALLATION AND <br />ELECTRONIC WIRING). <br />13 <br />