My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_1985-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2023 1:03:10 PM
Creation date
6/3/2020 9:49:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1996
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_1985-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7j <br />r7� <br />6. Overfill Protection System (spill catchment basin(s) reguired) <br />A. Nonmotor vehicle fuels (See Option 1A) <br />1. Level sensing device and #2 or #3 below <br />2. Audible/visual alarm triggered to liquid level sensor <br />3. Automatic shut-off device <br />B. Motor vehicle fuels only <br />1. Manual monitoring <br />a. Written filling procedure provided <br />b. Procedure addresses all of the following: <br />1) Visual monitoring of fuel level and filling operation <br />2) Available caacity of tank is at 103% or +200 gallons <br />(2635- 9) (AM)(C)) <br />3) Metered input <br />C. Spill catchment basin size <br />1. Minimum 5 gallons <br />Z"c <br />10. Secondary containers (Includes leak interception and detection systems). <br />A. Backfill in secondary container- Article 3, Section 2635) <br />I. See Article 3 Section 2635(c) (1-8). <br />B. Two or more primary containers within secondary container (Demonstrate <br />product compatibilities). <br />C. Liquids detected in secondary containment must be sampled and analyzed for <br />hazardous substances. (Article 3, Section 2635(6) and Health and Safety <br />Code 25291(e)(h). <br />D. Water tight cover for secondary container excavation (Article 3, Section <br />2635(7)). <br />11. Piping <br />A. Double c ntainment required for: <br />I. Product and vapor recovery lines. <br />2. Vent line (excluded only if ball float valve is installed). <br />
The URL can be used to link to this page
Your browser does not support the video tag.