My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 12:42:13 PM
Creation date
6/3/2020 9:49:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> WVIRONMENTAL HEALTH DEPARTMENT <br /> 304 East Weber Avenue, 3`d Floor, Stockton,CA 95202-2708 <br /> ` Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sj og v.or /g ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> Cor'ti( b Qbh%w�5 255` l� k;(.LA(- (4CAEA A <br /> Facility address:f It <br /> �t UST# L} 5 <br /> / <br /> LIDG 1,�t_` �5 Product �� l <br /> Facility Contact: Title: Phone: <br /> Monitoriinng�anel Piping system: Overfill prevention: <br /> eeFF ressurized ❑Suction ❑GravityMechanical ❑Audible/visual <br /> Inspection type: Violations: <br /> Routine Monitoring Certification ❑Installation ❑Other: ❑M1-RDetect ❑M2-RPrev ❑M-3 Both <br /> VIOLATION(S) HSC=Califomia Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation;RV=Re eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form) <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c 2 D Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i) Monitorin &response plan is onsite <br /> 7 CCR 2712 b Maintenance&monitoring records M1 <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 1 CCR 2632(c)(2) UST monitoring system is present (Ml) <br /> I 1 CCR 2630(d) UST system monitoring equipment is properly located to detect a leak (M1 <br /> 12 HSC 25291 UST system monitoring equipment isoperational M2 <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present M1) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 ( Line leak detectors are installed M1 <br /> 18 CCR 2635_(b)(1) Spill container (M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 CCR 2715 Designated Operator: (a)Statement from UST owner; (c-e)Monthly inspection;(f)Employee trainin <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (M1) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test Ml <br /> 28 1 CCR 2661 (f) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e Biennial tightness test of gravity piping( re-Janus 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping(pre-January 1, 1984) (Mi) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286(a) Permit to alter monitoring system <br /> 34 1 HSC 25298 ) Permit to temporarily close UST system <br /> 35 HSC 25298(c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 Other: <br /> EHD INSPECTOR: PHONE: UIC <br /> t . n u Septic system: <br /> V'✓V`"�-l 1"tl� ` ` OG Serves>_20 people/day <br /> RECEIVED BY: TITLE: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> ❑Dry wells/French Drains <br /> F"HD 23-02-002 <br />
The URL can be used to link to this page
Your browser does not support the video tag.