Laserfiche WebLink
MON RING SYSTEM CERTI ,ATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Statewide Petroleum (Valero) Bldg.No.: <br /> Site Address: 1700 E.Yosemite Ave. City: Manteca, Ca. Zip: 95336 <br /> Facility Contact Person: Sonny Contact Phone No.: (4 8) 230-8999 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 Date of Testing/Servicing: 7/16/2015 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the apero riate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: T1: 87 Tank ID: T2: 91 <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390-420 ®Annular Space or Vault Sensor. Model: 794390-420 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: VMI 99LD-2000 ®Mechanical Line Leak Detector. Model: VMI 99LD-2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on age <br /> Dispenser ID: 1&2 Dispenser ID: 3&4 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5&6 Dispenser ID: 7&8 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report; (check all that apply): ® System set-up ®Alarm history report <br /> Technician Name(print): Guadalupe Sanchez Sig r <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd. Oakdale, Ca.95361 Date of Testing/Servicing: 7/16/2015 <br /> Page 1 of 4 <br /> Rev(2/08) <br />