Laserfiche WebLink
SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br /> printouts from tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: Statewide Petroleum(Valero) Date of Testing: 7/16/2015 <br /> Facility Address: 1700 E.Yosemite Ave.,Manteca,Ca.95336 <br /> Facility Contact: Sonny I Phone: (408)230-8999 <br /> Date Local Agency Was Notified of Testing: ' ' i <br /> Name of Local Agency Inspector(f present during testing): Fatinah Zareef <br /> 2. TESTING CONTRACTOR INFORMATION AUG 2 8 2015 <br /> Company Name: Reliable Petroleum Services,Inc. <br /> Technician Conducting Test: Guadalupe Sanchez <br /> Credentials': x CSLB Contractor x ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Speci ) T <br /> License Number(s): 883706 5250451-UT <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: x Hydrostatic ❑Vacuum ❑Other <br /> Test Equipment Used: Standard Tape Measure Equipment Resolution:N/A <br /> Identify Spill Bucket(By Tank 1T1: 87 Fill 2 T2: 91 fill 3 4 <br /> Number, Stored Product, etc. <br /> Bucket Installation Type: x Direct Bury x Direct Bury ❑Direct Bury ❑Direct Bury <br /> ❑Contained in Sump ❑Contained in Sump ❑Contained in Sump ❑Contained in Sum <br /> Bucket Diameter: 12" 12" <br /> Bucket Depth: 141/4" 14" <br /> Wait time between applying 1 minute I minute <br /> vacuum/water and start of test: <br /> Test Start Time(Ti): 9:30 a.m. 9:30 a.m. <br /> Initial Reading(Ri): 131/4" 13" <br /> Test End Time(TF): 10:30 a.m. 10:30 a.m. <br /> Final Reading(RF): 131/4" 13" <br /> Test Duration(TF—TI): I hr 1 hr <br /> Change in Reading(RF-RI): 0 0 <br /> Pass/Fail Threshold or 1/16" 1/16" <br /> Criteria: <br /> Test Result: x Pass ElFail x Pass ❑Fail ❑ Pass Ct Fail 1w1 Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signa r ° Date 7/16/2015 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />