Laserfiche WebLink
Y <br /> SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of LIST spill containment structures. The completed form and <br /> printouts from tests(if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: Statewide Petroleum(Valero) Date of Testing: 7/31/2014 <br /> Facility Address: 1700 E.Yosemite Ave.,Manteca,Ca.95336 <br /> Facility Contact: Sonny Phone: (408)230-8999 <br /> Date Local Agency Was Notified of Testing: q -j <br /> Name of Local Agency Inspector(fpresent during testing): Elena Manzo <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: Reliable Petroleum Services,Inc. T <br /> Technician Conducting Test: Guadalupe Sanchez <br /> Credentials': x CSLB Contractor x ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Spec) <br /> License Number(s): 883706 5250451-UT <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: x Hydrostatic ❑Vacuum ❑Other <br /> Test Equipment Used: Standard Tape Measure Equipment Resolution:N/A <br /> Identify Spill Bucket(By Tank 1T1: 87 Fill 2 T2:91 fill 3 4 <br /> Number, Stored Product, etc. <br /> Bucket Installation Type: x Direct Bury x Direct Bury ❑Direct Bury ❑Direct Bury <br /> ❑Contained in Sump ❑Contained in Sump ❑Contained in Sump ❑Contained in Sum <br /> Bucket Diameter: 12" 12" <br /> Bucket Depth: 14" 14" <br /> Wait time between applying 1 minute 1 minute <br /> vacuum/water and start of test: <br /> Test Start Time(TI): 9:28 a.m. 9:28 a.m. <br /> Initial Reading(RI): 131/4" 13 1/8" <br /> Test End Time(TF): 10:28 a.m. 10:28 a.m. <br /> Final Reading(RF): 131/4" 13 1/8" <br /> Test Duration(TF—TI): 1 hr 1 hr <br /> Change in Reading(RF-RI): 0 0 <br /> Pass/Fail Threshold or 1/16" 1/16" <br /> Criteria: <br /> Test Result: x Pass ❑Fail x Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> —15 <br /> Technician's Signator c Date 7/31/2014 <br /> elf <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />