My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T 2:1 51 OCTANE <br />1.5 <br />PRODUCT CODE <br />2 <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />95.75 <br />TANK PROFILE <br />4 PTS <br />FULL VOL <br />12032 <br />71.8 INCH VOL <br />9697 <br />47.9 INCH VOL <br />6056 <br />23.9 INCH VOL <br />2386 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING <br />1.5 <br />HIGH WATER LIMIT: <br />2.0 <br />MAX OR LABEL VOL: <br />12032 <br />OVERFILL LIMIT <br />900/0 <br />10828 <br />HIGH PRODUCT <br />95% <br />11430 <br />DELIVERY LIMIT <br />20% <br />2406 <br />LOW PRODUCT <br />1000 <br />LEAK ALARM LIMIT: <br />50 <br />SUDDEN LOSS LIMIT: <br />50 <br />TANK TILT <br />6.00 <br />PROBE OFFSET <br />0.00 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />T#: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 20% <br />2406 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FHIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />JAN 29, 2009 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />- - - - - - - - - - - - <br />L I:DISPENSER 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 2:DISPENSER 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 3:DISPENSER 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 4:DISPENSER 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 5:87 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 6:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPADE <br />L 7:91 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 8:91 ANNULAR <br />TRI-STATE (SINGLE.FLOAT) <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />- - - - - - - - - - - - <br />R 1:87 RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: I <br />le IN -TANK ALARMS <br />T I:LEAK ALARM <br />T I:HIGH WATER ALARM <br />T I:LOW PRODUCT ALARM <br />T I:SUDDEN LOSS ALARM <br />T I:PERIODIC TEST FAIL <br />LIQUID SENSOR ALMS <br />L l:FUEL ALARM <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM. <br />L 2:SENSOR OUT ALARM <br />L 3:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />L 2:SHORT ALARM <br />L 3:SHORT ALARM <br />L 4:SHORT ALARM <br />L 5:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />ISD HOSE ALARMS <br />ALL:FLOW COLLECT FAIL <br />R 2:91 RELAY <br />TYPE' <br />Sl't;NDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />IN -TANK ALARMS <br />T 2:LEAK ALARM <br />T 2:HIGH WATER ALARM <br />T 2:LOW PRODUCT ALARM <br />T 2:SUDDEN LOSS ALARM <br />T 2:PERIODIC TEST FAIL <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />L 7:FUEL ALARM <br />L B:FUEL ALARM <br />L 2:SENSOR,OUT ALARM <br />L 3:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L G:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />L 2:SHORT ALARM <br />L 3:SHORT ALARM <br />L 4:SHORT ALARM <br />L 8:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />ISD HOSE ALARMS <br />ALL :,FLOW COLLECT FAIL <br />
The URL can be used to link to this page
Your browser does not support the video tag.