My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s6gov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Statewide Petroleum Inc <br /># <br />Facility 1700 E Yosemite Ave, Manteca <br />C2 <br />pection <br />Date: Jul 29, 2013 <br />Name: <br />Name: <br />HSC = California Health and SafetyCode; CCR = California Code of Regulations <br />Address: <br />File Review <br />101 HSC 25284 No permit to operate <br />Facility <br />Sunny Bhullar <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />Title: <br />President <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />Phone: <br />(209)823-7676 <br />Contact: <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 X CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (Mi) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (Mi) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />Inspection X Routine X Monitoring System <br />Type: <br />Certification n Installation ❑ Complaint - ID# <br />i Other: <br />(Authority HSC 25289) <br />SBhuller <br />y <br />Title: Owner <br />Consentfor. Xinspection XSampling (Photos <br />On Site Records <br />Grantedby:unn <br />Monitoring <br />Panel: TLS -350 <br />PipingVeeder-Root <br />System: <br />Syste <br />XPressurized iISuction nGravity <br />Preen ll <br />Prevention: <br />XMechanical I i Audible/visual <br />UST <br />4 <br />- <br />5 <br />- - <br />- - - <br />- - <br />-------------- <br />Product - <br />-87-octane <br />91 -octane <br />Designated <br />Robert'Barnhart <br />ICC Exp. <br />1-28-2014 <br />XViolations: M1 -Release Detection <br />u M2 -Release Prevention ] M3 -Both <br />Operator <br />Date: <br />On Site ServiceICC <br />Guadalupe Sanchez <br />Exp. Manufacturer's <br />Date: 4-20-2015 Training: VMI: 5-12-2015 <br />VMI: 11-8-2013 <br />Technician: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and SafetyCode; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not proVided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 X CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (Mi) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (Mi) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICG CA UST System Operator certification <br />115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to Gose UST system not obtained <br />On Site Records <br />201 <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/Y years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />CCR 2712(b) upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(1) Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />CCR 2650 was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector R Wed 4y: Title: <br />Elena Manzo (209) 953-7699 <br />
The URL can be used to link to this page
Your browser does not support the video tag.