Laserfiche WebLink
AlftJIFIED PROGRAM CONSOLIDATED FOR1Y <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - (Page 1 of 2) <br />TYPE OF ACTION ❑ 1. NEW PLAN ® 2. CHANGE OF INFORMATION <br />490-1 <br />PLAN TYPE ® 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br />490-2 <br />Teck one item only) ❑ 2. THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM( - <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />BUSINESS NAME (Same as FACILITY NAME) Yosemite 76 #255417 <br />7 <br />BUSINESS SITE ADDRESS 1700 East Yosemite Avenue lol. <br />CITY Manteca <br />104. <br />III EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br />Testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) must be performed at the frequency <br />specified by the equipment manufacturers' instructions, or annually, whichever is more frequent, and that such work must be performed by qualified personnel. <br />23 CCR '2632, 2634, 2638, 2641 <br />MONITORING EQUIPMENT IS SERVICED ® L ANNUALLY ❑ 99. OTHER (Specify): <br />490_3b <br />III. MONITORING LOCATIONS <br />N 1. NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. 1:12. SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR §2632, <br />2634)4904 <br />IV. TANK MONITORING IS PERFORMED USING THE,FOLLOWING METHOD(S): <br />® L CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT <br />490-5 <br />VAULT(S) WITH AUDIBLE AND VISUAL ALARMS. (23 CCR §2632,2634) <br />SECONDARY CONTAINMENT IS: ® a. DRY ❑ Elb. LIQUID FILLED c. PRESSURIZED E] d. UNDER VACUUM <br />- --- -- - <br />49° 6 <br />-8 <br />-----------_ -- - -- - - - --- - -- -- - - -- - --- _ __ _ - <br />47 1 MODEL #: TLS -350 <br />Veeder Root <br />MANUFACTURER_---- <br />48 <br />- -PANEL _ - - _ <br />LEAK SENSOR MANUFACTURER: Veeder Root 490-9' , MODEL #(S): 794380-420 <br />490.10 <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S). (23 CCR §2643) <br />490-11 <br />PANEL MANUFACTURER: 490-12. MODEL #: <br />----------___-- <br />490-17 <br />_-- - - --------------------------------------- - - -_ --- --- - --_ - -- - - -- - - ___ <br />IN -TANK PROBE MANUFACTURER: 490-14. MODEL #(S): <br />-------------------------------- <br />490. F5 <br />--- - - - _-- - - - - - - - ----- ----- ------ ---------- -------------------------------------- - - - --- -- - <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILY/NIGHTLY ❑ c. WEEKLY <br />490-16 <br />❑ d. MONTHLY ❑ e. OTHER (Specify): <br />P _ <br />490-17 <br />PROGRAMMED TESTS: ❑ a. 0.1 h. ❑ b. 0.2 h. ❑ c. OTHERS eci <br />g.p.h. g.p.h. (Specify): <br />490-18 <br />490-19 <br />3. MONTHLY STATISTICAL INVENTORY RECONCILIATION (23 CCR §2646.1): <br />490-20 <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) (23 CCR §2645). TESTING PERIOD: ❑ a. 36 HOURS ❑ b. 60 HOURS <br />490.21 <br />490-22 <br />❑ 5. TANK INTEGRITY TESTING (23 CCR §2643.1): <br />490-27 <br />490-24 <br />TEST FREQUENCY: Ela. ANNUALLY ❑ b. BIENNIALLY Elc. OTHER(Specify): P fY): <br />490-25 <br />490-26 <br />❑ 99. OTHER (Specify): <br />490-27 <br />V. PIPE MONITORING IS PERFORMED.USING THE FOLLOWING METHOD(S) (Check all that apply) <br />01. CONTINUOUS MONITORING OF PIPE/ PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND <br />490-2e <br />VISUAL ALARMS. (23 CCR §2636) <br />49429 <br />SECONDARY CONTAINMENT IS: Na. DRY ❑b. LIQUID FILLED ❑c. PRESSURIZED ❑d. UNDER VACUUM <br />---'--"------------ - <br />- - -_ <br />--------------490.30-T----- ----------- <br />--- -- -- --------- ------------- - - -- ---- --- -- - - - - - <br />PANEL MANUFACTURER: Veeder Root I MODEL #_TLS_350_ _ . __- _ <br />PANEL <br />490-71 <br />•--- <br />------ 490-32 ' <br />LEAK SENSOR MANUFACTURER: Veeder Root (MODEL #(S): 794380-208 <br />490-77 <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. N a. YES ❑ b. NO <br />490 34 <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. N a. YES ❑ b. NO <br />490-7s <br />N 2. MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS <br />OFF <br />PRODUCT FLOW WHEN A LEAK IS DETECTEDA23 CCR 12636)_____ <br />490-76 <br />MLLD MANUFACTURER(S): Va orless 490.77 MODEL #(s): LD2000 <br />49x78 <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS (23 CCR §2636) <br />---------- - ------ -- --- - - - - - - <br />490-79 <br />- - <br />- ---- - - - - -------- -- - --- - - ---- ---.---- <br />_ - ELLD MANUFACTURER(S) 490-4°. i MODEL #(S): <br />------ ---- -------------'--- <br />490.41 <br />-------------------____-_------ ------------- ----------------------------------------------- --------------i--`------------------------------------- <br />PROGRAMMED IN LINE LEAK TEST: ❑ 1. MINIMUM MONTHLY 0.2g•p• h. ❑ 2. MINIMUM ANNUAL 0.1 g.p.h.49° <br />42 <br />490-47 <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. [Ia. YES Elb. NO <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES El b. NO <br />490 <br />❑ 4. PIPE INTEGRITY TESTING 49045 <br />TEST FREQUENCY ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS ❑ c. OTHER (Specify) 49046490-47 <br />5. VISUAL PIPE MONITORING. <br />49048 <br />FREQUENCY ❑ a. DAILY ❑ b. WEEKLY ❑ c. MIN. MONTHLY & EACH TIME SYSTEM OPERATED- <br />490-49 <br />Allowed for monitoring of unburied emergency enerator fuel piping only per HSC §25281.5(6)(3 <br />6. SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR §2636(a)(3)1. <br />490-50 <br />7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br />490-51 <br />-99. <br />490-52 <br />Fol OTHER (Specify) <br />490-57 <br />UPCF UST -D (12/2007) <br />