My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I lv,7. <br />S W RCB, January 2002 Page 1- of <br />4. TANK ANNULAR TESMG <br />Test Method Developed By: <br />p Tank Manufacturer R industry Standard D Professional Enginear <br />o Other eet&J <br />Test Method Used: <br />U Pressure <br />V Vacuum <br />O Hydrostatic <br />0 Other,(S eon) <br />Test Equipment Used: 4 f n . <br />DIAL GAUGE <br />Equipment Resolution: . 5% <br />;. �• <br />h' Tank #v $'7 <br />Tank# n„ q( <br />Tank# Tank# <br />is Tank Exempt From Testing?t <br />0 Yes ?RNo <br />0 Yes 7®"No <br />O Yes 0 No 0 Yes P. No <br />'rank Capacity: <br />Zo cxq) <br />000 <br />Tank Material., <br />Tank Manufacturer: <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />A,n,,- <br />f nitial Reading (R)): <br />fQ <br />Test End Time: <br />Final Reading (Rr): <br />Test Duration: <br />Change in Reading (RF -Rt): <br />Jar, <br />Pass/Fail Threshold or Criteitia: <br />4:,r I <br />Test Result: <br />Pass 0 Fall <br />Pass 0 Fail i <br />0 Pass 0 Fail 0 Pass 0 Fail <br />Was sensor removed for testing? <br />Yes O No 0 NA <br />"MYes D No 0 NA <br />0 Yes O No ONA 0 Yes 0 No ONA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes 0 No 0 NA <br />es 0 No 0 NA <br />O Yes 0 No . DNA 0 Yes 0 No 0 NA <br />Comments — include i ormatiorr on re airs modeprior to testln andrecomnrended ollow-v or failed tests <br />Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (Califomia Code of Regulations, Title 23, Section 2637(a)(6)} <br />