My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. kesults of Testing/Servicin <br />Software Version Installed: 15.01 <br />Complete the following checklist: <br />n <br />L] Yes <br />❑ No* <br />Is the audible alarm operational? <br />Yes <br />No* <br />Is the Visual alarm operational? <br />x Yes <br />gxx <br />No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes <br />❑ No* <br />Were all sensors installed at the lowest point of secondary containment and positioned so that other <br />equipment will not interfere with their proper operation? <br />Yes <br />No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />HxN/A <br />operational? <br />x Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br />❑ N/A <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: <br />which sensors initate positive shut -down? ❑ Sump/Trench Sensors [x]Dispenser Containment Sensors <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnected? L] Yes; ❑ No; <br />❑ Yes <br />® No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />Fx ] N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at <br />the tank fill point(s) and operating properly? If so, at what percent of tank capasity does the alarm <br />trigger? E= % <br />❑ Yes* <br />❑ No <br />Was any monitoring equipment replaced? If Yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? <br />Product; ❑ Water. If yes, describe causes in Section E, below. <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />Kt] <br />No* <br />Is all monitoring equipment operational per manufacturer's specifications? 11 <br />* In Section E below, discribe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />