My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N,J O A Q U I N Environmental Health Department <br /> COUNTY <br /> >. rider round Storage Tank Pro rarn dna action Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA VALERO 1700 E YOSEMITE AVE, MANTECA August 02, 2018 <br /> SUMMARY OF VIOLATIONS _ <br /> (CLASS i,CLASS Ii,or;MINOR-Notioe to Comply), <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 9/7/17 and an inspection report was issued identifying information to be submitted to <br /> bring this site into compliance. This information was required to be submitted by 10/17/17. This information was <br /> received on 4/30/18 resulting in a non-compliant status for this facility. An operator that receives an inspection <br /> report shall have 30 days to submit a written response that includes a statement documenting corrective actions <br /> taken or proposing corrective actions which will be taken. Ensure that a written response documenting corrective <br /> actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class 11 violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these approved plans shall <br /> be accessible on site at all times. Immediately locate and retain an approved copy on site.The cashier on site was <br /> able to make the corrections to the monitoring plan while inspector was on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> This is a minor violation. <br /> 211 CCR 2715(0(2)Designated operator employee training not performed or log not kept. <br /> The designated operator employee training did not indicated the hire dates for the employees that she has trained. <br /> The designated operator shall train facility employees for which he or she is responsible in the proper operation and <br /> maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> FA0003796 PR0231454 SCO01 08/02/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.