My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_1986-1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 4:40:23 PM
Creation date
6/3/2020 9:49:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1995
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_1986-1995.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
mC.m.x:. :.fa .. ., w+. :... i..••.... A. :.. .., P �..;.!??TF^.a.�+,71: +«i'ak:.@Lh"ibxd .: v.: _. . r ._ <br />r i 1 <br />/eak /okator <br />LD2000 <br />ENV>RONMEWAL.SERVKiES,VJM <br />115 DEWALT AVENUE, N.W. <br />SUITE 400 <br />CANTON, OH 44702 <br />216-453-1800 800-523-4370 <br />TYPE OF PUMP <br />TEST <br />RESULTS <br />MINUTES <br />APPLIED <br />DATE OF TEST <br />CONTRACT NUMBER <br />CUSTOMER <br />1'.1- ?,- <br />,LOCATION <br />NO. <br />PRODUCT <br />REMOTE <br />LOCATION - IDENTIFICATION NUMBER <br />NAME <br />ADDRESS <br />CITY <br />STATE <br />TEST RESULTS SUMMARY <br />LEAK LOKATOR USE <br />ONLY <br />SYSTEM <br />TANK SIZE <br />WATER <br />INCHES <br />LEAK LOKATOR RESULTS" <br />J <br />CONCL. CODE <br />PRODUCT <br />GALLONS <br />DIA/MATL <br />LEVEL <br />INCHES <br />ALR <br />GPH <br />CONCLUSION <br />RECOMMENDATIONS <br />TEST TANK SYS <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT <br />OTHER INFORMATION _ <br />PRODUCT LINES - HYDROSTATIC PRFSSItRF TFCT 09:elu Tc <br />SYSTEM <br />TYPE OF PUMP <br /># <br />APPLIED <br />MINUTES <br />APPLIED <br />PRODUCT <br />LOSS <br />CC`S <br />PRODUCT <br />LOSS <br />GPH <br />CONCLUSION/ <br />RESULT <br />NO. <br />PRODUCT <br />REMOTE <br />SUCTION <br />J <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT <br />UC114111-yr 1Ca1 nCOUL110 <br />" LEVEL - INCHES FROM TANK BOTTOM TO TEST LEVEL <br />ALR - ABSOLUTE LEAK RATE (MEASURED LEAK RATE - TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br />CONCLUSION - NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br />CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight at full <br />system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />TESTS CONDUCTED BY <br />TEMPERATURE <br />COMPENSATION <br />TEST VAN NO. <br />TANK TESTING SPECIALIST <br />SIGNATURE <br />DATE <br />TANK TESTING SPECIALIST <br />=1 <br />NAME <br />TITLE <br />, <br />" LEVEL - INCHES FROM TANK BOTTOM TO TEST LEVEL <br />ALR - ABSOLUTE LEAK RATE (MEASURED LEAK RATE - TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br />CONCLUSION - NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br />CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight at full <br />system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />TESTS CONDUCTED BY <br />CERTIFIED BY <br />TEST VAN NO. <br />TANK TESTING SPECIALIST <br />SIGNATURE <br />DATE <br />TANK TESTING SPECIALIST <br />=1 <br />NAME <br />TITLE <br />, <br />
The URL can be used to link to this page
Your browser does not support the video tag.