Laserfiche WebLink
r <br />``HU'IT R ENVIRONMENTAL SERVIC10 INC. pza W FINAL TEST RESULTS <br />15405 REDHILL AVENUE, SUITE C TEST DATE: 3-16-87 <br />IUSTIN, CALIFORNIA 92680 SEP 2 8 1987 <br />800-247-9014 800-247-2186 <br />ENVIROMENTAL HEALTH <br />CUSTOMER: Shell LOCATION/IDENTIFICA TION®SERVICES NUM ER <br />204-6522-0307 <br />ADDRESS: 4-'t East Main <br />Ripon, CA <br />TEST RESULTS SUMMARY <br />System <br />Tank <br />Size <br />No. <br />Product <br />Gallons <br />Dia_ /Matt <br />I <br />Super <br />101000 <br />95 <br />2 <br />U/L <br />8000 <br />•95 <br />3 <br />R/L <br />8000 <br />95 <br />TEST RESULTS SUMMARY <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />No. <br />System <br />Product <br />Leak <br />Lokator Results* <br />Water <br />Level <br />ALR <br />I <br />2 <br />3 <br />Inches <br />Inches <br />GPH <br />Conclusion Recommendations <br />0 <br />160 <br />-.021 <br />Tight <br />0 <br />158 <br />-.012 <br />Tight <br />0 <br />i59 <br />-.013 <br />Tight <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />No. <br />System <br />Product <br />TYae of <br />Remote <br />e <br />Pumo Pounds <br />Su ction A lied <br />Pounds <br />Held <br />Minutes Product Product <br />Held Loss CC's Loss GPH <br />Conclusion <br />/Result <br />I <br />2 <br />3 <br />Super <br />U/L <br />R/L <br />Red Jacket <br />Red Jacket <br />Red Jacket <br />50 <br />50 <br />50 <br />48 <br />49 <br />46 <br />10 <br />10 <br />10 <br />Tight <br />Tight <br />Tight <br />Note: <br />On suction systems, <br />NEVER put more than <br />15 psi <br />on any pump system. <br />DETAIL OF TEST RESULTS <br />Test Time Leak Rate Temperature <br />System Test Level Clock Duration Absolute Check <br />No. Product No. Compensation Leak Rate Test <br />tIn I Start (Hr-Min} CC/DIV CC/MIN Del_ t__a- CC/MIN CC/MIN GPH Y/N <br />1 Super. 1 160 1:40 0-31 +2.166 +13.924 + .034 +15.282 -1.357 -.021 Na <br />2 U/L 1 158 2:30 0-31 +1.652 +13.774 + .038 +13.016 + .757 +.012 No <br />3 R/L 1 159 3:40 0-30 -1.467 - 9.430 - .030 -10.275 - .845 -.013 <br />Na <br />*Level - Inches from Tank Bottom to Test Level <br />Conclusion - NFPA 329 criterion of + <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per <br />0.05 GPH is used to certify tightness Hour <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRO <br />SERVICES, INC. LEAK LOKATOR according to all standard operating MENTAL <br />procedures. <br />as tight at full system meet the criterion established by the National Fire Protectionicated <br />Association Pamphlet 329 for Precision Testing. <br />Tests Conducted BY: Test Van No. LL -21 <br />Tank Testing pecialist: Mark McBride <br />Team Manage P t IYheeler <br />Certified By: <br />Mic)4el L. Anesetti, Field Supervisor <br />y�y d <br />Date <br />