Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FOR TANK: TA0506091 <br /> PR#: PR0231477 <br /> UNDERGROUND STORAGE TANKS -TANK�AJ� FAC#: FA0003753 <br /> () PWPI (two pages per tank) <br /> Page 2 of 5 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check only item only) <br /> s 'B r °"r a / ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMITi� : . % ITO <br /> , ., ., ,�i, ,r) y ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Sam as FACILITY NAME m DBA-Doing.Business As) FACILITY ID: PR#: 1 <br /> RIPON SHELL* 3 FA0003753 PR0231477 <br /> LOCATION WITHIN SITE(optional) 341 E MAIN ST,RIPON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 5 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ❑No 434 <br /> TA0506091 XERXES If"Yes",conplete one page fm each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 12/1/1995 15,000 <br /> ADDITIONAL DESCRIPTION(Fm local use only) 438 <br /> R.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEHICLE FUEL ® la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked cor plete Petrolean Type) <br /> ❑ 16.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ 1 c.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory p 8a e CAS# fHazardous °ry page)Hazardous Materials Invent aaz <br /> E] 4.HAZARDOUS WASTE ) 4al ( <br /> (Includes Used Oil) REGULAR <br /> ❑95.UNKNOWN <br /> M.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one itcm only) ❑ 2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ L BARE STEEL ® 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING E] 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) E] 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (For local we only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> E]2 SACRIFICIAL ANODE (Fm local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> ® I SPILL CONTAINMENT 1,996.00 <br /> (Check all that apply) 1,996.00 ® I ALARM 1,998.00 ® 3 FILL TUBE SHUT OFF VAL` 119"'M <br /> 7r❑ 2 DROP TUBE 1.,996 Z UV^+ 0�� ❑ 2 BALL ❑ 4 EXEMPT Z0113 <br /> ❑X 3 STRIKER PLATE 1,996.00 FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shad be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check me item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />