Laserfiche WebLink
MONITORING S STEM EQUIPMENT CER-RIFICATION <br /> State and local laws regulations require that equipment which monitors tanks and/or piping systems containing hazardous <br /> materials be tested/serviced annually or on a schedule specified by the manufacturer,whichever is more frequent. This form,or a <br /> service report with equivalent information,must be used to document testing and servicing of monitoring equipment. If more <br /> than one monitoring system(e.g.Veeder-Root TLS-350,Ronan X76S,etc.)is installed at the facility,a separate certification or <br /> report must be prepared for each monitoring system by the technician who performs the work. <br /> Date of Testing/Servicing: 3-24-00 Facility Name: Shell <br /> Site Address: 341 E.Main St. City: Ripon Zip: 95366 <br /> Facility Contact Person: D.Griffin Contact Phone No.: (209)599-4454 <br /> Make/Model of Monitoring System: Veeder Root/Simplicity Location of Control Panel: Behind Register <br /> Make/Model of Line Leak Detector(LLD): Veeder Root/PLLD LLD Leak Threshold: 3.0 g.p.h. <br /> Complete the following checklist: <br /> X Yes No* Monitoring system isoperable per manufacturer's specifications? <br /> X Yes No* Audible alarm isoperational? <br /> X Yes No* Visual alarm isoperational? <br /> X Yes No* Monitoring system is secured from unauthorized tampering? <br /> X Yes No* For pressurized piping systems,do the turbines automatically shut down if the monitoring system detects a leak,fails <br /> to operate,or is electrically disconnected? If yes,which monitoring devices initiate positive shut down? <br /> N/A <br /> PLLD/Sump Sensor <br /> X Yes No* For monitoring systems which serve as tank overfill warning devices,does the overfill warning function operate <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 90% <br /> N/A <br /> *In the comments section below,describe how and when these deficiencies will be corrected. <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID No.: Regular Tank ID No.: Premium Tank ID No.: Tank ID No.: <br /> Annular Space Sensor X Annular Space Sensor Annular Space Sensor Annular Space Sensor <br /> Piping Sump Sensor X Piping Sump Sensor Piping Sump Sensor Piping Sump Sensor <br /> In-Tank Gauging Probe X In-Tank Gauging Probe In-Tank Gauging Probe In-Tank Gauging Probe <br /> Dispenser Containment Sensor(s) X Dispenser Containment Sensor(s) Dispenser Containment Sensor(s) Dispenser Containment Sensor(s) <br /> Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector <br /> Electronic Line Leak Detector X Electronic Line Leak Detector Electronic Line Leak Detector Electronic Line Leak Detector <br /> Fill Sump Sensor Fill Sump Sensor Fill Sump Sensor Fill Sump Sensor <br /> TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor <br /> Are impact valves operational per manufacturer's specifications? I I YES IX INO <br /> Comments: <br /> I certify that the equipment identified above was inspected/serviced in accordance with manufacturers' guidelines. <br /> Attached to this Certification is information(e.g.manufacturer's checklist,etc.)necessary to verify that the above <br /> information is correct and to describe any repairs,replacement,or recalibration of equipment. <br /> Name of Qualified Technician(print): John Talbott Signature: Signature on file at SSS <br /> Testing Company Name: Service Station Systems,Inc. Phone No.: (408)971-2445 <br />