My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:34:13 PM
Creation date
6/3/2020 9:50:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI 0 <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the: technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility <br />RE <br />N.- <br />Site 341 <br />AddrPcc <br />Facility Contact <br />PPrcnn• <br />Make/Model of Mc <br />SHELL <br />T MAIN ST <br />ANGLE <br />System: VEEDER ROOT TLS350 <br />Bldg. No.: <br />city: RIPON <br />Zip: <br />Contact Phone No.: (209) 599-4454 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Date of Testing/Servicing: 1/24/2011 <br />Tank ID: 87 <br />Tank ID: <br />Z In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />Z Annular Space or Vault Sensor. <br />Model: <br />302 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />1 ❑ Mechanical Line Leak Detector. <br />Model: <br />Z Electronic Line Leak Detector, <br />Model: <br />PLLD <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: 91 <br />Z In -Tank Gauging Probe. <br />Model: MAG I <br />❑ in -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. <br />Model <br />Z Annular Space or Vault Sensor. <br />Model: 302 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector, <br />Model: <br />Z Electronic Line Leak Detector. <br />Model: PLLD <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />El (specify equipment type and model in Section E on Page 2). <br />❑Other (specify equipment type and model in Section E on Page 2), <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />Z Dispenser Containment Sensor(s). <br />Model: <br />001 <br />Z Dispenser Containment Sensor(s). <br />Model: 001 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />Z Dispenser Containment Sensor(s). <br />Model: <br />001 <br />Z Dispenser Containment Sensor(s). <br />Model: 001 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s), <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(:,). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanKs! or dispensers, copy tins torm. Inciuce mtormation for every tal and aispenser at line faculty. <br />C. Certification - I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification Is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Piot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): Z System set-up Z Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: <br />Certification No.: 5263321Llf CA UTT2206 Nevada UST26756 Oregon License No: 04-1676 CA 2206 Nevada 26755 Oregon _ <br />Testing Company Name: AF -ORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2' ` STREET GALT, CA 95632 Date of Testing/Servicing: <br />1-24-11 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.