My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:34:13 PM
Creation date
6/3/2020 9:50:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 is <br />0 Page )- of —1 <br />Test Method Developed By: Tank Manufacturer 0 Industry Standard 0 Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: 0 Pressure Vacuum 0 Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: <br />I Equipment Resolution: <br />N <br />Tank # i Tank # 2 <br />Tank # Tank # <br />Is Tank Exempt From Testing., X Yes No X Yes No <br />0 Yes 0 No 0 Yes D No <br />Tank Capacity: <br />15K <br />15K <br />Tank Material: <br />Fiberglass <br />Fiberglass <br />Tank Manufacturer: <br />XERXES <br />XERXES <br />Product Stored: <br />Regular 87 <br />Supreme 91 <br />Wait time between applying <br />Exempt <br />Exempt <br />vacuum and starting test: <br />See Comments <br />See Comments <br />Test Start Time: <br />itial Reading (R,): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Pass ❑ Fail <br />PassFail <br />❑ Pass 0 Fail ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />0 No ❑ NA <br />0 No DNA <br />0 Yes ❑ No 0 NA 0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />Yes 0 No 0 NA <br />Yes 0 No 0 NA <br />0 Yes 0 No 0 NA 0 Yes 0 No 0 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Tanks have brine filled Annulars, and are exempt from periodic Testing.! <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.