Laserfiche WebLink
I <br />SWRCB, January 2002 Is <br />VARGO-11 <br />0 Page 5 of <br />Test Method Developed By: 0 UDC Manufacturer 0 Industry Standard X Professional Engineer <br />0 Other (Specify) <br />Test Method Used: D Pressure D Vacuum X Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />� ­ . <br />pv, '77,10 �7-7-77; <br />101�L�;Z` <br />1�111­4,; <br />UDC # 1&2 UDC #3&4 <br />UDC #5&6 UDC #7&8 <br />UDC Manufacturer: Unknown Unknown <br />Unknown Unknown <br />UDC Material: <br />Poly Plastic <br />Poly Plastic <br />Poly Plastic <br />Poly Plastic <br />UDC Depth: <br />26" <br />26" <br />26 1/2" <br />27" <br />Height from UDC Bottom to Top <br />7" <br />8" <br />71/211 <br />8" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />4" <br />411 <br />415 <br />459 <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Dry <br />Dry <br />Dry <br />Dry <br />testing: <br />Portion of UDC Tested' <br />Water Line 11" <br />Water Line 10" <br />Water Line 12" <br />Water Line 12" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />Yes X No 0 NA <br />Yes X No 0 NA <br />Yes X No 0 NA <br />Yes X No DNA <br />product and water)?* <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />Was fail-safe verified to be <br />operational?* <br />0 Yes X No 0 NA <br />0 Yes X No 0 NA <br />0 Yes X No 0 NA <br />0 Yes X No 0 NA <br />Wait time between applying <br />10 Minutes <br />10 Minutes <br />10 Minutes <br />10 Minutes <br />water and starting test <br />Test Start Time: <br />10:20 <br />10:55 <br />11:00 <br />11:05 <br />Initial Reading (Rj): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />10:50 <br />11:25 <br />11:30 <br />11:35 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-Rj): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />00ALIP_4�utes <br />.005/30,.Ninutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />( x Pass" I <br />X Pass 0 Fall <br />X Pass 0 Fail <br />Was sensor removed for testing? <br />X-Ve—sD No 0 NA <br />XYes ONo [INA <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after testim? <br />X Yes 0 No DNA <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />X Yes 0 No 0 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />