My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:34:13 PM
Creation date
6/3/2020 9:50:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPAISER CONTAINMENT fADC) TESTING <br />Test Method By: O Manufacturer <br />Test Method Uses: O Pressure <br />Measuring Equipment Used: INCON <br />• Industry Standard o Professional Engr o Other (see below) <br />O Vacuum • Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 112 <br />Disp # 314 <br />Disp # 516 <br />Disp # 718 <br />0:05 <br />UDC manufacturer <br />Unknown <br />Unknown <br />Unknown <br />Unknown <br />10:07 AM <br />Initial Probe Reading <br />UDC material <br />FRP <br />FRP <br />FRP <br />FRP <br />10:01 AM <br />10:01 AM <br />UDC depth (inches) <br />25 <br />25 <br />26 <br />26 <br />5.9625 <br />5.5740 <br />Height from UDC bottom to highest <br />piping penetration <br />6 <br />8 <br />6 <br />8 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />Height from UDC bottom to lowest <br />electrical penetration <br />4 <br />4 <br />3 <br />4 <br />0.0020 <br />0.0020 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Yes <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replace <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />9 <br />11 <br />9 <br />11 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />9:46 AM <br />9:46 AM <br />9:46 AM <br />10:07 AM <br />Initial Probe Reading <br />5.6153 <br />5.1011 <br />5.9619 <br />5.5741 <br />Test end time <br />10:01 AM <br />10:01 AM <br />10:01 AM <br />10:22 AM <br />Final Probe Reading <br />5.6150 <br />5.1010 <br />5.9625 <br />5.5740 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0001 <br />0.0006 <br />-0.0001 <br />Pass/Fail threshold (10.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />d after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />9 <br />11 <br />9 <br />11 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />9:46 AM <br />9:46 AM <br />9:46 AM <br />10:07 AM <br />Initial Probe Reading <br />5.6153 <br />5.1011 <br />5.9619 <br />5.5741 <br />Test end time <br />10:01 AM <br />10:01 AM <br />10:01 AM <br />10:22 AM <br />Final Probe Reading <br />5.6150 <br />5.1010 <br />5.9625 <br />5.5740 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0001 <br />0.0006 <br />-0.0001 <br />Pass/Fail threshold (10.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.