Laserfiche WebLink
UNDER DISPAISER CONTAINMENT fADC) TESTING <br />Test Method By: O Manufacturer <br />Test Method Uses: O Pressure <br />Measuring Equipment Used: INCON <br />• Industry Standard o Professional Engr o Other (see below) <br />O Vacuum • Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 112 <br />Disp # 314 <br />Disp # 516 <br />Disp # 718 <br />0:05 <br />UDC manufacturer <br />Unknown <br />Unknown <br />Unknown <br />Unknown <br />10:07 AM <br />Initial Probe Reading <br />UDC material <br />FRP <br />FRP <br />FRP <br />FRP <br />10:01 AM <br />10:01 AM <br />UDC depth (inches) <br />25 <br />25 <br />26 <br />26 <br />5.9625 <br />5.5740 <br />Height from UDC bottom to highest <br />piping penetration <br />6 <br />8 <br />6 <br />8 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />Height from UDC bottom to lowest <br />electrical penetration <br />4 <br />4 <br />3 <br />4 <br />0.0020 <br />0.0020 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Yes <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replace <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />9 <br />11 <br />9 <br />11 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />9:46 AM <br />9:46 AM <br />9:46 AM <br />10:07 AM <br />Initial Probe Reading <br />5.6153 <br />5.1011 <br />5.9619 <br />5.5741 <br />Test end time <br />10:01 AM <br />10:01 AM <br />10:01 AM <br />10:22 AM <br />Final Probe Reading <br />5.6150 <br />5.1010 <br />5.9625 <br />5.5740 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0001 <br />0.0006 <br />-0.0001 <br />Pass/Fail threshold (10.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />d after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />9 <br />11 <br />9 <br />11 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />9:46 AM <br />9:46 AM <br />9:46 AM <br />10:07 AM <br />Initial Probe Reading <br />5.6153 <br />5.1011 <br />5.9619 <br />5.5741 <br />Test end time <br />10:01 AM <br />10:01 AM <br />10:01 AM <br />10:22 AM <br />Final Probe Reading <br />5.6150 <br />5.1010 <br />5.9625 <br />5.5740 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0001 <br />0.0006 <br />-0.0001 <br />Pass/Fail threshold (10.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />2006 Walton Engineering, Inc. <br />