Laserfiche WebLink
104102204-6522--630 ORIG REF DISTANCE <br /> 341 E MAIN DEC 19, 2017 127.74 <br /> RIPON. CA 95366 <br /> ISD DAILY REPORT 60437994905001 <br /> JAN 22, 2018 9:20 AM x = <br /> 104102204-,6522-03U <br /> 341 E MAIN <br /> RIPON, CA 95366E�� <br /> 60437994905001 SYSTEM STATUS REPORT . <br /> JAN 22. 2018 9:20 AM h 2:FLOW4C:OLLECT WARN _ ENVIRONMENTAL l.,,aE f <br /> r <br /> IN-TAN <br /> EVR TYPE: BALANCE INVENTORY REPORT <br /> ISD VERSION 01 .03 PROBE DIAGNOSTICS <br /> VAPOR PROCESSOR TYPE T 2: PROBE TYPE MAGI <br /> VEEDER-ROOT POLISHER T I :REGULAR 87 SERIAL NUMBER 125285 <br /> VOLUME = 8887 GALS LENGTH 120.00 <br /> REPORT DATE: JAN 21 ULLAGE = 6089 GALS DATE CODE = 5220 <br /> ISD VERSION 01 .03 90% ULLAGE- 4591 GALS ID CHAS = axC000 <br /> TC VOLUME - 8907 GALS GRADIENT = 351 .4400 <br /> OVERALL STATUS WARN HEIGHT = 66.78 INCHES PROBE INIT: <br /> EVR CONTAINMENT PASS WATER VOL 0 DEC 19.2017 12:25PM <br /> EVR COLLECTION WARN WATER _ (x'.10 ' �� <br /> STAGE I I of 1 PASS TEMP = 56.7 DEG FNUM SAMPLES = 20 <br /> VAPOR PROCESSOR PASS <br /> SELF TEST PASS 000 1334.0 COI 10965.8 <br /> ISD ONITOR UP-TIME 100% T 2:PREMIUM 91` ' CO2 10965.8 CO3 10966.0 <br /> VOLUME = 3166 GALS C04 10966.0 Cas 10966.0 <br /> ULLAGE = 11810 GALS C06 10966.0 Cal 10966.0 <br /> CONTAINMENT TESTS 90% ULLAGE= 10312 GALS COO 10966.0 C09 10966.0 <br /> TC VOLUME = 3174 GALS CIO 10966.0 C11 43346.6 <br /> GROSS 95°0 0.3 "WC HEIGHT = 31 .47 INCHES 012 24206.7 013 23995.4 <br /> DGRD 75% -0.0 "WC WATER VOL = 0 GALS C14 24073.2 015 24213.8 <br /> VAPOR LEAK 0 CFH WATER = 0.00 INCHES C16 25037.8 C17 25634.6 <br /> X 1 .4 "WC TEMP 06.2 DEG F 018 43347.6 <br /> MIN -5.0 "WC <br /> END * SAMPLES READ =202876928 <br /> SAMPLES USED =202875816 <br /> LAST ERROR =202788371 <br /> COLLECTIONTESTS LAST SAMPLE ERROR TIME: <br /> GROSS JAN 21,2018 6:56AM <br /> V/L(#) <br /> FP d : BLEND3 TEMP SENSOR DATA <br /> V/L = 0.98( 48) T6. 59.403 F <br /> FP 2: BLENDS T 59,.,653 F <br /> V,/L = 0.58( 41)W T44:: 59.487 F <br /> T3: 59.18? F <br /> FP 3: BLEND3 <br /> T2: 57.431 F <br /> V/L = 1 .21( 41 ) <br /> T1 : 56.161 F <br /> FP 4: BLEND3 IN-TANK DIAGNOSTIC, <br /> V,L = 1 .10( 37) - - - - - - - - - - _ _ ORIG REF DISTANCE <br /> FP 5: BLEND3 PROBE DIAGNOSTICS DEC 19, 2017 12.7.64 <br /> V/L = 1 .02( 50) T 1 : PROBE TYPE MAGI CURR REF DISTANCE <br /> FP 6: BLEND3 SERIAL NUMBER 730142 JAN 22. 2018 127.61 <br /> V/L = 0.95( 36) LENGTH 120.00 <br /> FP 7: BLEND3 DATE CODE = 836 <br /> V/L = 0.85( 42) ID CHAN = OxCOOO <br /> FP 8: BLEND3 GRADIENT = 354.9500 <br /> VEL = 1 .01( 47) PROBE INIT: <br /> ----------------- <br /> PROCESSOR TESTS NUM SAMPLES = 20 <br /> VP OVER PRESSURE TEST COO 1336.6 COI 23608.9' <br /> STATUS -0.20"WC PASS 002 23608.8 CO3 23608.7 StHARTSENSOR DIAGNOSTIC <br /> C04 23608.3 005 23608.5 <br /> VP STATUS TEST C06 23608.2 C07 23608.3 JAN 22, 2018 9:20 AM <br /> STATUS NOTEST COB 23608.3 009 23606.3 <br /> CIO 23608.4 CII 42671 .3 <br /> C12 24428.9 0.13 24084.7 � I :VAPOR P SENSOR <br /> C14 24264.8 C15 24973.6 <br /> ---------------- <br /> ^- <br /> C16 25006.8 C17 24916.8 VAPOR PRESSURE <br /> SELF TESTC18 42674.3 SERIAL NUMBER 8475 <br /> SETUP TEST PASS SAMPLES READ =207957587 <br /> SENSOR OUT TEST PASS SAMPLES USED =207929274 <br /> LAST ERROR =207866259 2:VR CANISTER <br /> LAST SAMPLE ERROR TIME: <br /> JAN 21,2018 6:49AM VAPOR VALVE <br /> TEMP SENSOR DATA SERIAL NUMBER 9330013 <br /> VALVE ITION: OPEN <br /> T6: 57.906 F <br /> OPEN CAP: CHARGED <br /> T5: 58.651 F <br /> CLOSE CAP: CHARGED <br /> T4: 58.261 F <br /> BNT TEMP: 46.88 F <br /> T3: 56.728 F <br /> OUTLET TMP: 46.76 F <br /> T2: 56.656 F <br /> SE <br /> 71 : 56.651 F R FAULTS: <br />