My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:34:13 PM
Creation date
6/3/2020 9:50:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> •• <br /> V_' ? wkWimAjPSMELL <br /> sa <br /> UST Tank cERSID <br /> 341 E MAIN ST TA0506091 10181381 <br /> ;RIPON,CA 95366 Tank Info:Installed Date:4/25/143612:00:00 AM-Tank Use:Motor Vehicle Fueling•Tank <br /> Contents:Regular Unleaded-Type Of Tank:Double Wall-Piping Construction:Double- <br /> Pipe Monitoring as Perfi arced 11iii he Foli®WrngeYfRO�gS� c uta s w led v 5 <br /> al <br /> Yes Continuous Monitoring of Piping Secondary Containment w <br /> .. . ', <br /> I <br /> Piping Secondary Containment Panel Manufacturer <br /> Leak Sensor Manufacturer <br /> Dry Veeder Root Veeder Root , ! <br /> Panel Model# leak Sensor Model# �� <br /> TLS-350 208 <br /> Yes Leak Alarm Triggers Automatic Pump Shutdown FEB 27 217 <br /> Yes Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Line Leak Detector Performs 3 GPH Leak Test <br /> MLLD Manufacturer MLLD Model <br /> i <br /> Yes Electronic Line Leak Detector Performs 3 GPH Leak Test <br /> iELLD Manufacturer ELLD Programmed In-Line Testing ELLD Triggers Automatic Pump Shutdown <br /> Veeder Root Yes <br /> ELLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br /> TLS-350 Yes <br /> Pipeline Integrity Testing Visual Pipeline Monitoring <br /> I <br /> I'Yipeline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br /> I <br /> Suction Piping Meets Exemption Criteria 1I <br /> No Regulated Piping Per Health and Safety Code,Division 20,Chapter 6.7 Is Connected To The Tank System i <br /> Other Pipeline Monitoring <br /> Under Dispenser.Container►enttl £ iUloiatarfr� <br /> UDC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> ;Continuous Yes <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown C <br /> 2 L't' <br /> DC Panel Manufacturer Yes <br /> Veeder Root Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> ;UDC Panel Model# Yes ��## <br /> TLS-350 <br /> UDC Monitoring Stops Flow of Product at Dispenser <br /> t DC Leak Sensor Manufacturer <br /> Yes <br /> Veeder Root UDC Construction r <br /> IiiDC Leak Sensor Model Single-walled <br /> �21 UDC Secondary Containment Monitoring <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> Periodic Systet7l y <br /> ELD Testing <br /> Yes Secondary Containment Testing <br /> Yes Spill Bucket Testing <br /> Printed on 2/25/2017 7:42 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.