My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1984-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1984-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 4:43:47 PM
Creation date
6/3/2020 9:50:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1984-1998
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1984-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN CO#PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEALVISION <br /> I_ WORKSHEET FOR SITE CLOSURE EVALUATION * DATE] <br /> NAME OF FACILITY JETANKPSID <br /> ECODE <br /> ADDRESS # - <br /> TANK SIZE FUEL TYPE <br /> II. GENERAL SITE HISTORY <br /> *** <br /> Is permit current? Yes No Permit # - Facility Status Code Doc.SOiI/GW Cont Yes Noil <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year Average Annual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & Type Irr Dan Pub <br /> S Score S Score S Score <br /> Distance to Wells) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxx None one one <br /> COLUMN TOTALS>>>TOTAL POINTS + + <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> B T X E B IT X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sade Result: GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the teaching potential <br /> analysis. (i.e., site is currently of UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes No <br /> 2. Recommend Site Closure Yes No *If Yes, Refer to Site Mitigation for Evaluation I IF <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.