COMPLIANCE INFO_1984-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1984-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 4:43:47 PM
Creation date
6/3/2020 9:50:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1984-1998
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1984-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FE Petro is pleased to introduce the first <br />monitor the pumping demand at the station <br />significant advancement in submersible pump <br />forecourt. By varying the RPM of the motor, the <br />technology since Franklin Electric, FE Petro's <br />pumping rate is controlled to maintain a constant <br />corporate parent, engineered the first <br />flow rate at the dispenser nozzle. This, combined <br />submersible motor for use in underground <br />with additional "Intelligence" provides advantages <br />storage tanks back in the mid 1950's. Essentially, <br />not previously available from any submersible <br />this original motor design is still in use today. <br />pumping unit. <br />The FE Petro Intelligent Submersible Turbine <br />Consider these specific features of the IST for <br />(IST) utilizes a Variable Frequency Controller to <br />your retail operations: <br />CONSTANT FLOW: <br />Provides constant flow for up to 8 nozzles at a <br />predetermined flow rate set at installation. <br />Constant flow means faster fueling times during <br />those daily peak business periods. <br />MEETS EPA "SPITBACK" CONTROL: <br />From January 1 <br />1996, the EPA <br />requires a maximum <br />flow rate per nozzle <br />of 10 GPM. The IST <br />meets this require- <br />ment with a one <br />time investment. To <br />comply, the maxi- <br />mum flow rate for <br />one nozzle is adjust- <br />ed to a maximum of <br />10 GPM. The IST will <br />provide a constant <br />flow rate for up to 8 <br />nozzles operating <br />simultaneously. <br />EPA mandated "Spitback" control is met by the <br />IST with a simple adjustment during installation. <br />Invest in "Spitback" control one time with <br />the IST. <br />DRY RUNNING PROTECTION: <br />Since the IST monitors the <br />power consumption of the <br />motor, the Variable <br />Frequency Controller <br />turns the pump off upon, <br />the tank being pumped <br />empty. The controller sig- <br />nals the dry running con- <br />dition as well as others. <br />Dry running is eliminated with the IST. The <br />result is less bearing wear, and longer motor life. <br />- VARIABLE LENGTH: <br />Finally, one pump that fits 94% of all known <br />tank diameters and tank bury depth <br />combinations. Two other model <br />lengths are available to handle <br />installations shorter or longer <br />than this range. The tele- <br />scoping connection is <br />patent pending by <br />FE Petro. <br />0 0 <br />• • <br />Pump length is set at the job site by making one S • <br />simple measurement and setting the pump <br />length. All in about 20 minutes and without <br />affecting the UL listing of the pump. <br />9 <br />MANUAL PRESSURE RELIEF: <br />Another unique FE PE <br />feature. When necess, <br />during maintenance t, <br />bleed line pressure to <br />a vent screw is provide <br />By turning this screw, <br />line pressure is divert <br />back to the tank. <br />Reduces fuel discharge into the sump manhole or <br />dispenser pan during servicing, further protecting <br />service technicians and the environment. <br />A RELIABLE CHECK VALVE: <br />The IST uses FE Petro's <br />proven line check <br />valve. At 2 3/4" in <br />diameter, this valve <br />reduces pressure loss <br />at high flow rates, <br />resulting in faster <br />fueling times and lower <br />power consumption. <br />The FE Petro check valve is proven to seal. You <br />can avoid purchasing additional check valves <br />when the IST is used with some electronic line <br />leak detectors because of this proven reliability. <br />SUPERIOR BEARING COOLING: <br />The IST uses the <br />exclusive <br />FE Petro cooling <br />system. This unique <br />system continually <br />passes over 1 GPM <br />through a fine <br />bronze filter and <br />directly through <br />motor bearings <br />whenever pump is <br />operating. <br />This system has been designed to extend critical <br />bearing and motor life. <br />PRESSURE RELIEF VALVE: <br />The IST pressure relief valve is the same simple <br />valve used for years in our standard <br />submersibles. Factory set to relieve (, <br />at or above pump pressure. <br />This valve is protected <br />from particles in the <br />fuel by a fine., <br />mesh screen. <br />By keeping static line pressure as high as <br />possible, mechanical leak detectors make <br />fewer tests, and therefore last longer. <br />The IST uses the <br />standard <br />FE Petro air <br />eliminator, <br />which has a <br />double function <br />as the syphon <br />primer for tank <br />syphon systems. <br />AIR ELIMINATOR: <br />The air eliminator is a one way valve, allowing <br />air to return to the tank, but not re-enter the <br />piping system. <br />SYPHON CHECK VALVE: <br />Optional for syphoned tanks. <br />Another time proven performer. <br />The FE Petro syphon check valve can be <br />easily cleaned in the field. It is not necessary <br />to replace with a new valve if it becomes <br />blocked from particles in the fuel tanks. <br />VERTICAL DISCHARGE <br />Another unique feature of FE Petro. Provides <br />for a simple connection to underground piping. <br />This unique FE Petro feature allows for fewer <br />fittings to connect the pump to the discharge <br />line, and requires less space in the sump. <br />If ever required, <br />the pump can be <br />easily removed <br />from the tank by <br />unthreading <br />three bolts. There <br />is no need to <br />disconnect the <br />syphon system, <br />or remove the <br />leak detector <br />from the system <br />to service the IST. <br />SIMPLE SERVICING <br />This feature reduces the risk of correcting <br />one problem and causing another. <br />INTELLIGENCE: <br />The Variable Frequency Controller has contin- <br />uous running diagnostics and displays system <br />conditions on the controller. <br />Dry Running <br />Low Incoming Voltage <br />Locked Rotor in Pump <br />Open Circuit between <br />Controller and Motor <br />Short Circuit between ewe <br />Controller and Motor <br />Thermal Overload in Controller <br />Controller capacitors failing <br />Immediate, easily understood, display of <br />system conditions. <br />SERIAL COMMUNICATION <br />Incorporates a �"" ""� <br />serial commun <br />system for easy <br />integration or i <br />monitoring. <br />System integration with other electronic <br />monitoring equipment. <br />Power Requirements: <br />Variable Frequency Controller Input Power <br />200/250 Volt,1 or 3 phase, 50 or 60 Hz <br />Motor <br />Three phase, power provided by variable <br />frequency controller. <br />Pump Motor: <br />2 HP, 2 stage centrifugal pump <br />Maximum liquid viscosity: <br />70 SSU at 60 deg F, <br />capable of pumping ballast water from <br />underground tanks. <br />Maximum flow rate -100 GPM at full flow <br />Maximum Pressure -126 feet of head <br />(42 PSI in gasoline) <br />Maximum Amperage - 9 amps at full load <br />Check Valve: <br />• 2 3/4" (70mm) diameter constructed of Alcohol <br />compatible alodined aluminum and steel <br />with fluorocarbon seal. <br />Pressure Relief Valve: <br />• Set to relieve static line pressure at 40-50 PSI, <br />reseals above 20 PSI. <br />Seal Elastomers: <br />• All wetted seals are Fluorocarbon. <br />Syphon: <br />Syphon Primer is venturi type, capable <br />of 26" Hg vacuum <br />Syphon Check Valve is machined aluminum, <br />field repairable <br />Variable Frequency Controller Size: <br />Enclosure Size is 51/8" wide by 10" high <br />by 81/4" deep <br />Alcohol/Gasoline Compatible: <br />A standard feature. The IST will handle any <br />mixture of alcohol in gasoline, up to 100% <br />methanol or ethanol, and up to 20% MTBE, <br />20% ETBE, or 179/6 TAME. <br />Approvals: <br />. UL, others pending <br />Quality Certification: <br />FE Petro is an ISO 9001 Certified manufacturer. <br />