My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nov. 15. 2005 9.00RM Star Environmental, Inc. No. 3742 P. 8 <br /> SWRCB, JAnuary 2002 Mage 7 of <br /> 9. SPILL/OVERFILL CONTAINMENT BOX—FS <br /> Facility is Not Equipped WithSpill/overni I Containment Boxes <br /> Spill/Overfill Containment Boxes are Present,but wem Not Tested I <br /> Test Method Developed By: Spill Bucket Manufacturer Industry Standard o essional Engineer <br /> Other(Specify) CSWRI3 <br /> Test Method Used: Pressure Vacuum hydrostatic <br /> Other(Specify) X <br /> Test Equipment Used: RAPID CONTROLS BOX, MTS PROBE u�pment so tton: 002 <br /> Split Box 87v Spill Box#87 fill Spill Boa#gl. v Spill Bos#sl t,ft <br /> Bucket Diameter, 12" __. 12" 12" _ 12" <br /> Bucket Depth: �...... 12" A_.., 12" _ 12" 12" <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: 130 min. <br /> X30 min. 30 min. 30 min. <br /> Test Start Time: 10:00 am 10.30 am 11:00 am 11:30 am <br /> initial Reading(RI): 0.000 0.000 0.000 0.000 j <br /> Test End Time: 10.30 am 11.00 am 11:30 am 12-00 pm i <br /> Final Reading(PW): 0.000 0.000 0.000 <br /> Test Duration: _30 min_ 30 min. 30 min_ 30 min. _ <br /> Change in Reading(IZF-R1): ^ 0.E000 0.000 0.000 0.000 <br /> Pass ai o or .002 .002 .002 .002 <br /> Criteria: _ <br /> Test Result: �W_....... _ pass Fail Pass Fail Pass_ .,fail Pass tail <br /> Comments- (include information on repairs made prior to testing, and recommended fallow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.