My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE 7L? loci <br />SAN JOAQUIN COUNTY PR# <br />ENVIRONMENTAL HEALTH DEPARTMENT PAGE [ el= 2- <br />304 <br />304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br />(209) 468-3420 <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Name ESCaIvN MIA; AAI— Facility Address /0'? -7 If .YOSe,-' -"4e , L. e.. ,LSCA CEJ <br />Facilty Contact RAWS05L, Title Dom— Phone # F3 g ` t'r`1C' <br />UST# L� Product__%_1 UST#5 Product C, I UST#_Product UST# Product <br />Overfill Prevention: ❑Audible/Visual XMechanical Monitoring Panel46e^JA�'Ao5-A,"K J7,• <br />Piping System: ❑ Gravity Pressure ❑ Suction Violations: )'Minor ❑ Major <br />Automatic Pump Shut Down Satisfies CCR 2636 ( Yes ❑ No Dispenser Pan: KYes ❑ No <br />INSPECTION TYPE: >LRoutine %Monitoring Certification ❑Complaint ❑Install ❑Removal ❑Repair/Upgrade <br />COMPANY NAME: We i- S4A - EvTECHNICIAN NAME: oi.i E PHONE: ( 4&-,)�oYY—c1? 79 <br />VIOLATION(S) <br />The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br />California Code of Regulations (CCR): <br />1 <br />HSC 25284 <br />Permit to operate <br />20 <br />CCR 2712 (b) <br />Maintenance & monitoring <br />2 <br />CCR 2637 <br />Secondary cont testing (6 <br />records <br />month/36 month) <br />21 <br />CCR 2636 (f)(4) <br />Annual line tightness test <br />3�CCR <br />2711(b) & (c) <br />Current State Forms A & B <br />22 <br />CCR 2630 (d) <br />Annual line leak detector test <br />4 <br />HSC 25292.2 <br />Certification of financial <br />23 <br />CCR 2630 (d) <br />Annual monitoring certification <br />responsibility and letter from <br />24 <br />CCR 2643 (d) <br />Daily monitoring of suction <br />2630 <br />chief financial officer <br />Continuous monitoring system <br />piping that is not continuously <br />monitored <br />5_,Z/ <br />CCR (d) <br />for UST system <br />25 <br />CCR 2636 (a) <br />Conventional suction piping <br />6 <br />CCR 2636 (c)(1) <br />All releases in secondary piping <br />shall have continuous <br />flow to a collection sump <br />monitoring & 20 containment <br />7 <br />HSC 25291 (e) <br />Water in secondary (20) cont <br />26 <br />CCR 2643 (e) <br />Biennial tightness test of gravity <br />8 <br />HSC 25291 (f) <br />Automatic line leak detector(s) <br />piping that is not continuously <br />9 <br />CCR 2636 (f)(1) <br />Continuous monitoring system <br />monitored <br />for underground piping <br />27 <br />CCR 2662 <br />Upgrade requirements for UST <br />10 <br />CCR 2632 (c)(2) <br />Continuous monitoring system <br />V <br />system <br />for UST <br />28 <br />CCR 2661 <br />Permit to repair UST system <br />11 <br />HSC 25291(a)(2) <br />Secondary containment for <br />29 <br />HSC 25286 (a) <br />Permit to alter monitoring <br />UST is tight <br />system <br />12 <br />CCR 2636 (f)(1) <br />Continuous monitoring system <br />30 <br />HSC 25298 (a) <br />Illegal abandonment of UST <br />13 <br />CCR 2635 (b)(1) <br />for dispenser system <br />Spill container <br />31 <br />HSC 25298 (b) <br />system <br />Permit to temporarily close US- <br />14 <br />CCR 2635 (b)(2) <br />Overfill prevention system <br />system <br />15 <br />CCR 2631 (a) <br />Primary containment is product- <br />32 <br />HSC 25298 (c) <br />Permit to close UST system <br />tight <br />33 <br />HSC 25291 (e) <br />Water in 20 cont analyzed and <br />16 <br />HSC 25292.1 <br />UST system is operated to <br />properly disposed of <br />prevent unauthorized release <br />34 <br />CCR 2640 (e) <br />Single wall component within <br />17 <br />CCR 2650 <br />Recording/reporting <br />1 000'of Public Well, no ELD <br />unauthorized release <br />35 <br />CCR 2635(a)(2)(A) Cathodic protection testing <br />18 <br />CCR 2632 (d) <br />Monitoring & response plan <br />36 <br />H&SC 25299(a)(9) Disabling leak detect. devices <br />19 <br />CCR 2712 (i) <br />Monitoring & response plan is <br />37 <br />Violation(s) not listed above <br />on site <br />EHD INSPECTOR: <br />1 A -e vb'A Fjt <br />PHONE: <br />RECEIVED BY: <br />TITLE: <br />• 7% <br />c r <br />UNITIII/UST/INSP (rev 724/02) <br />
The URL can be used to link to this page
Your browser does not support the video tag.