COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 2:11:22 PM
Creation date
6/3/2020 9:50:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br />• MONITORING PLAN - PAGE 2 <br />VI. DISPENSER MONITORING <br />MONITORING OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) Myo. <br />❑ 1. CONTINUOUS ELECTRONIC MONITORING F UNDElf DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER:yV M51 MODEL #: MSz. <br />Msa. <br />LEAK SENSOR MANUFACTURER: Mss. MODEL #(S): <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? T&a. YES ❑ b. NO Mss. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? a. YES ❑ b. NO M56. <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? a. YES ❑ b. NO MSz. <br />❑ 2. MECHANICAL ASSEMBLY (e.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: MSs. MODEL #(S): M <br />M6600. . <br />❑ 3.VISUAL MONITORING DONE: a. DAILY El b. b. WEEKLY (Requires agency approv <br />❑ 4. NO DISPENSERS 1 <br />M61. <br />❑ 99. OTHER (Specify) <br />VII. ENIIANCED'LEAK DETECTION ; <br />❑ 1. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70 <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. ' TRAINING <br />REF RENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) M80 <br />1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. ❑❑❑ OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />3. ❑ THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of 7/1/2004) <br />4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. CALIFORNIA UNDERGROUND STORAGE TANK LAW — <br />STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />6. <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />M81 <br />99. ❑ OTHER (Specify): <br />00 Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br />By July 1, 2004, this facility will have a "Designated UST Operator" who has passed the operator exam administered by the International Code Council (ICC). By July <br />"Designated Operator" train facility employees in the proper operation and maintenance of the UST systems. This <br />1, 2004, and annually thereafter, the UST will <br />training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the leak detection equipment. <br />➢ The facility employee's role with regard to spills and overfills. <br />➢ Whom to contact for emergencies and leak detection alarms. <br />lr.r facility employees hired on or after July 1, 2004, the initial training will be conducted within 30 days of the date of hire. <br />IX. COMMENTSIADDITIONAL INFORMATION <br />Please use this section to include any additional UST system monitoring-related information (e.g., additional information required by your local agency): Mas. <br />X. PERSONNEL RESPONSIBILITIES <br />AS OF 7/1/2004, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION – <br />FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br />EQUIPMENT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br />UST SYSTEMS IN ACCORDANCE WITH 23 CCR § 2715(b). <br />XI. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />OWNER/OPERATOR SIGNATURE REPRESENTING DATE: M91 <br />Owner Myo. <br />Gv" ^ Operator <br />M9z.OWNER/OPERATOR <br />OWNER/OPERATOR NAME (print): <br />VT <br />TITLE: M93 <br />(Agency Use Only) This plan has been reviewed and: Approved ❑ Approved With Conditions ❑ Disapproved <br />Local Agency Signature: Date: <br />Comments/Special Conditions: <br />SJCEHD-d (07/03) - 3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.