My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D/ w4a <br /> UED PROGRAM CONSOLIDATED FORIS / 13 <br /> UNDERGROUND STORAGE TANK <br /> OPERA'T'ING PERMIT APPLICATION -TANK INFORMA'I*ON Onc form per UST-) <br /> fYPF.OI'ACTION E L NEW SLLE PERMIT ❑ 3.RENEWAL PERMIT E] 5.CHANGE OF INFORMATION 430 <br /> (Check only it-,only) 6.TEMPORARY SLIT;CLOSURE ❑ 7.PERMANENTLY CLOSED ON SLLE ❑ 8.TANK REMOVED <br /> DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 430b <br /> 1.RACIliITY'TNTOIiIVTATION <br /> FACILITY ID#(Agency Use Only) FA0000279 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> ESCALON MINI MART <br /> BUSINESS SITE ADDRESS 03 CITY 104 <br /> 1097 YOSEMITE AVE ESCALON <br /> III.'rANKDESCRIPTION ' <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION:THIS TANK IS 434 <br /> ❑ 1.A STAND-ALONE TANK <br /> TA0507900 JOOR <br /> ❑X 2.ONE IN A COMPARTMENTED UNIT <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 05/15/1998 7,000 " 2 <br /> IIT.TANK I ISE AND CONTENTS <br /> TANK USE 0 la.MOTOR VEI IICLE FUEL ❑ ib.MARINA FUELING ❑ lc.AVIATION FUELING <br /> ❑ 3.CI IEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE ❑ 5.EMERGENCY GENERATOR FUEL <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Snecifv): <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑x Ib.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): <br /> NON-PETROLEUM: ❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Snecifv): 440b <br /> [V.TANI 'CONS'tRiJCTION" ' . ..., <br /> TYPE OF TANK ❑1.SINGLE WALL ❑x 2.DOUBLE WALL ❑95 UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑X 3.FIBERGLASS ❑6.INTERNAL BLADDER 444 <br /> ❑7.STEEL+INTERNAL LINING ❑95.UNKNOWN ❑ 99.OTHER 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑X 3.FIBERGLASS ❑6.EXTERIOR MEMBRANE LINER ❑7.JACKETED 445 <br /> ❑98.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify) <br /> OVERFILL PREVENTION ❑ 1.AUDIBLE&VISUAL ALARMS ❑ 2 BALL FLOAT 1 3 FILL TUBE SHUT OFF VALVE 452 <br /> ❑4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> ��a{x8w'I'RODUGILWASTEPM! GTOft <br /> Ita 3 <br /> .. 1 <br /> PIPING CONSTRUCTION 1.SINGLE WALLED 2.DOUBLE-WALLED ❑ 99.OTHER" 460 <br /> SYSTEM TYPE 1.PRESSURE ❑2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑4.FIBERGLASS tW8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE [:195.UNKNOWN ❑ 99.OTHER 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑4.FIBERGLASSFLEXIBLE EI 10.RIGIDPLASTIC <br /> 464b <br /> E] 90.NONE ❑95.UNKNOWN ]�99.OTHER 464c <br /> PIPING/TURBINE CONI'AINNIENT SUMP TYPE I.SINGLE-WALLED ❑ 2.DOUBLE-WALLED ❑ 99.NONE 464d <br /> -•'VL VENT:VAPOR RECOVERY(YR),AND RISERIFII PIPE PIPING CONSTUCIION 3I <br /> . � r <br /> ;. d, f <br /> VEN L PIRMARY CON'T'AINMENT ❑ L S F L ❑X 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER 464e <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC jja7 90.NONE ❑ 99.OTHER 464f <br /> VR PIRMARY CONTAINMENT ❑ 1.STEEL MF 4.FIBERGLASS ❑ 12.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER 4648 <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 12.RIGID PLASTIC 4W 90.NONE ❑ 99.OTHER 464h <br /> VENT PIPING TRANS...SUMP TYPE ❑ 1.SINGLE-WALLED ❑ 12.DOUBLE-WALLED 4W9.NONE 464' <br /> RISER PIRMARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS ❑ 12.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER 464j <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 12.RIGID PLASTIC ja 90.NONE ❑ 99.OTHER 464k <br /> FILL COMPONENTS INSTALLED 1.SPILL BUCKET ❑ 3.STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 45la-c <br /> >VII:UNDER DISPENSER:CONTAINIVIENT(UDC) <br /> CONSTRUCTION TYPE 1.SINGLE-WALLED ❑ 2.DOUBLE-WALLED ❑ 3.NO DISPENSERS ❑90.NONE 469a <br /> CONTRUCTION MATERIAL ❑ 1.STEEL dW 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER r 469b-c <br /> Zft A-4 <br /> ft <br /> 0M P <br /> ` 4'VIII'CORROSION PROTEGTIOl e �;!I {'=.3 <br /> , „ <br /> 449 <br /> S'iEEL COMPONENT PROTECTION ❑ 2.SACRAFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT 6.ISOLATION <br /> 4 °l r IX APPI .0 SIG1Vi 1 I <br /> 1 certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accura E nd in full <br /> compliance with legal requirements. �/ d J <br /> �.71I� �• <br /> APPLICANT SIGNATURE y�l�jF«t. DATE _ G �;''-'°� -7 470 <br /> APPLICANT NAME(print) BALWINDER SINGH 471 APPLICANT TITLE OWNER 472 <br />
The URL can be used to link to this page
Your browser does not support the video tag.