My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2010-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 3:25:18 PM
Creation date
6/3/2020 9:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2014
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2010-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
487
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification 0 <br /> D. Results of Testing/Servicing <br /> Software Version installed: AS3E31G <br /> FCom lete the followin checklist: <br /> 0 yes 0 No* Is the audible alarm operational? <br /> 0 Yes 0 No* Is the visual alarm operational.? <br /> 0 Yes 0 No* Were all sensors vi <br /> EW sually i ted,�funonally tested,and confirmed operational? <br /> N Yes 0 No* Were all sensors installed at lowest point of 9-co nt and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> station, is all communications equipment (e.g., modem) <br /> 0 Yes 0 No* If alarms are relayed to a remote monitoring <br /> 10 N/A Operational? <br /> g yes 0 No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> 171 N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: -which sensors <br /> initiate positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; 0 Dispenser Containment <br /> Sensors. 9 Yes; [I No. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection'? <br /> ❑ Yes [I No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> g N/A mechanical overfill prevention valve is installed),is the overfill warning alarin visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> Yes* 0 No Was any monitoring equipment replacW7 If yes, identify specific sensors, probes, or other equipment <br /> ❑ replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> 0 Yes* [I No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> [I Product; [I Water. If yes,describe causes in Section E,below. <br /> 0 Yes F-I No* Was monitoring system set-up.reviewe.d toe proper settings?Attach set up reports, if applicable <br /> 0 Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: ALL ITEMS TESTED PASS. RECEIVED <br /> il''Xj �j " <br /> - 9 A <br /> ENVIRONMENTAL <br /> HEALTH DEPARTMENT <br />