A& da <br /> 1W 1W <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.s*qov.or-q/ehd <br /> -Und,06660-ttorage Unk`PfddiamInspection;Rdb&t <br /> Facility Name: Facility Address: Date: <br /> ESCALON MINI MART 1097 YOSEMITE AVE, ESCALON December 13,2017 <br /> USTSystem Obseilvations i <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements c V Ei R Ei COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden Ei V Ei R o COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ci V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status E V ii R u COS <br /> 324 CCR 2717.1(g) Tampered with red tag Ei V Ei R Ei COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R Ej COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms Ei V Ei R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ci V o R ci COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements Ei V Ei R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ci V o R ci COS <br /> 330 CCR 26360(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump Ei V ii R Ei COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards Ei V Ei R E COS <br /> Sin <br /> -Walled.Non- <br /> 16 Ped UnUdc <br /> I <br /> pkflq <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve Ei V o R Ei COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ci V o R Ei COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) Ej V Ej R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) Ei V c R o COS <br /> Other Violations <br /> n <br /> 2010 See below Unlisted General violation ❑V ii R ii COS <br /> SUMMARY <br /> OPVIOLATIONS <br /> (CLASS 1 or GLASS 11 66 to comply)- <br /> 2, <br /> Item# Remarks <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees. <br /> A permit to operate the LIST system has not been issued due to outstanding violations. This violations include <br /> failing to to maintain records of follow up actions for alarms that occurred and an incorrect plot plan. No person may <br /> own or operate an UST unless a permit for its operation has been issued by the local agency to the owner or <br /> operator of the UST system. Immediately obtain a permit to operate a UST system from the EHD. <br /> This is a Class I violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> LIST Tank Information forms for the 87 grade and 91 grade tanks are not current in CERS. Under Vent,Vapor <br /> Recovery(VR)and Riser/Fill Pipe Piping Construction, under Fill Components Installed, change"NO"to"YES"for <br /> striker plate/bottom protector. Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information,and submit for review by the EHD. <br /> This is a Class 11 violation. <br /> FA0000279 PR0231497 SC001 12/13/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 6 Underground Storage Tank Program OIR <br />