Laserfiche WebLink
1411111111V low <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.so_ov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ESCALON MINI MART 1097 YOSEMITE AVE, ESCALON December 13,2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply)' <br /> Item# Remarks <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months. <br /> The February 2017, March 2017, July 2017 and August 2017 designated operator monthly inspection reports were <br /> not found on site during the inspection.The designated operator, Felix Ramirez,was on site during the inspection <br /> and printed them out. Designated operator monthly inspection reports for the previous twelve months shall be <br /> retained on site. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> During the inspection, liquid was observed on top of the filters in the 8/7 under dispenser containment unit. Liquid <br /> was observed on the piping below the fuel filter as well. The piping and the fuel filter were wet. The technician's <br /> assistant on site put his hand on the filter and scraped his finger along the surface. There was a brown tar like <br /> substance that came off with a liquid. Both the technician, Felix Ramirez, and his assistant said that the liquid was <br /> probably coming from the fuel filter. The technician assistant wiped off the liquid on the filter. The underground <br /> storage tank system shall be operated to prevent unauthorized releases. Immediately make a determination to see <br /> where the liquid is coming from and send the repair records to EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 12,2018. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: December 13,2017 Inspector: Inspector Phone: <br /> Printed Name and Title: JOHN ALANIZ, EH Specialist (209)468-3147 <br /> Bill Singh, Owner <br /> FA0000279 PR0231497 SCO01 12/13/2017 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 6 Underground Storage Tank Program 01R <br />