My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility Name: <br />ESCALON MINI MART <br />`W San Joaquin County MW <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fan: (209) 468-3433 Web: www.sjaov.org/ehd <br />Facility Address: <br />1097 YOSEMITE AVE, ESCALON <br />Date: <br />January 08, 2015 <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V <br />❑ R <br />❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V <br />❑ R <br />❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V <br />❑ R <br />❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V <br />❑ R <br />❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R <br />❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br />402 CCR 2643(d) Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R ❑ COS <br />403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V <br />❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V <br />❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V <br />❑ R <br />❑ COS <br />Item # I Remarks <br />103 HSC 25292.2 Current financial responsibility documents not submitted. <br />Complete and/or accurate financial responsibility documents have not been submitted to the EHD. Current financial <br />responsibility documents are required to be submitted annually. The submitted financial responsibility lacked witness's <br />name and a signature date. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, upload the required documents. This is a repeat violation, Class II. <br />109 CCR 2637 Failed to test secondary containment. <br />The most recent secondary containment testing results from December 19-20, 2012, indicated a failure at UDC 3/4 and <br />UDC 5/6. All secondary containment for the UST system must be tight. A permit was obtained from the EHD on March <br />15, 2013 (SR0066337) to repair the aforementioned components. According to an email communication from <br />Franzen -Hill Corporation, dated April 17, 2013, a successful secondary containment test was conducted for the UDC <br />5/6 on March 25, 2013. According to the aforementioned correspondence, additional repairs are still necessary for the <br />UDC 1/2. Immediately have a properly licensed, trained, and certified contractor repair or replace the failed <br />components under permit and inspection from the EHD. This is a repeat violation, Class II. <br />__V•.__ _, ` ,. T' ELENA MANZO, REHS ( k"',- 209) 953-7699 101/08/2015 <br />6A pn w <br />3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.