My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAK3JOAQUIN Environmental Health Department <br /> C 0 U N'T Y <br /> 'VFUnderground lge 7r Program Inspection 0A <br /> d' <br /> Facility Name: Facility Address: Date: <br /> ESCALON MINI MART 1097 YOSEMITE AVE, ESCALON December 18, 2018 <br /> UST System 06eirVatipris'! <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight o V Ei R Ei COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) w V n R m COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) c V o R Ei COS <br /> 25290.2(c3) <br /> 317 CCR 2636,2643(c)(1), Line leak detector(LLD)not installed Ei V o R Ei COS <br /> 2666(f) <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch Ei V o R Ei COS <br /> 319 CCR 2635,2637.1, No spill bucket,failed to contain 5 gallons,no means to keep it empty,or failed to be tested D V Ei R Ei COS <br /> 2665,2712 <br /> 320 CCR 2635,2637.2, Failure to comply with the installation,inspection,or record keeping of the overfill prevention n V Ei R w COS <br /> 2665,2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ci V Ei R ci COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status Ei V o R Ei COS <br /> 323 HSC 25283.5(a) Unburied below grade LIST system failed to meet exemption status o V Ei R Ei COS <br /> 324 CCR 2717.1(g) Tampered with red tag Ei V Ei R D COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged LIST D V Ei R c COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms m V Ei R c COS <br /> 327 CCR 2631.1 LIST system not compatible with the substance stored o V o R Ei COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V Ei R Ei COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V D R ci COS <br /> 330 CCR 2636(f),2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm Ei V o R Ei COS <br /> 2666(f) <br /> 331 CCR 2630(d),2641(a) Liquid does not flow into the sump in the event of a leak(i.e.,failure to remove test boot). E:i V Ei R o COS <br /> 332 CCR 2631(b&d), Primary and/or secondary containment not constructed in accordance with the established standards Ei V c R D COS <br /> 2666(b&e) <br /> 333 CCR 2635,2636(b), Failure to comply with the cathodic protection system requirements Ei V Ei R Ei COS <br /> 2662,2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair Ei V Ei R o COS <br /> 335 CCR 2630,2632,2643, Equipment or methods used to monitor the LIST system are not certified by an independent third-party ci V o R o COS <br /> 2644.1 <br /> g in6le <br /> -Wallpo Non-Pressurizedf ,PipIng <br /> & <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve o V Ei R D COS <br /> 2641(b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). o V o R Ei COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) D V Ei R o COS <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) 11 V c R [i COS <br /> A, <br /> '7 <br /> -T, <br /> J§ <br /> 2010 See below Unlisted General violation o V Ei R Ei COS <br /> w'. L�,MM#RY�,,l 014- <br /> Ls <br /> OE�VIOU <br /> vl <br /> (�[�"ASS LASS N It,or Noi� tot 0 <br /> W <br /> oFi�',�qr N" <br /> FA0000279 PR0231497 SC001 12/18/2018 <br /> EHD 23-01 Rev.09128/2018 Page 3 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue Stockton, California 95205 1 T 209 468-3420 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.