COMPLIANCE INFO_1997-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 4:00:13 PM
Creation date
6/3/2020 9:50:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. -,. -..< .... w _. ...,:.. ...-n.ic. r :.�mm .P' ...:-. `.��.,Y«s` 3�'&=4 _ -s'npb^i.rvx....-3j.s. ...q....: y�g..4•,rC+^,smr w. ,re.+_ _ .— „ -.. <br /> '�bOUAC!].0 <br /> STATE OF CALIFORNIA +� <br /> STATE WATER RESOURCES CONTROL BOARD 3 g <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B p� <br /> *� C'+L�RMS► <br /> COMPLETE A SEPARATE FORM FOREACH TANK SYSTEM. so <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION PERMANENTL ON S <br /> ONE ITEM F__] 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE TANK RE;YD <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: L\7 � <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# ) B. MANUFACTURED BY: m <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANKCAPACITY IN GALLONS: 60 DOD <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A. ❑rv1 MOTOR VEHICLE FUEL ❑ 4 OIL B, C to REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> 'UNLEADED ❑ 4 GASAHOL E:] 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1b PREMIUM <br /> �1 PRODUCT ❑ lc MIDGRADE UNLEADED.❑ 5 JET FUEL <br /> E] 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE 8 M85 <br /> IBE IN ITEM D.BELOPn <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> 1 DOUBLE WALL 3 SINGLE WALL WITH EXTERIOR LINER 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> A. TYPE OF ❑❑ " ❑ ❑ <br /> SYSTEM- I r`• 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑r' 4 STEEL CLAD W1 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED 2 ALKYD LINING ❑ 3 EPDXY LINING ❑` 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING HIS UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION �. <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL etc. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE ROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A'U' 1 SUCTION A 41A PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A'U-`1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A'V-"4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION Ej 1 MECHANICAL UNE LEAK2 UNE TIGHTNESS 3 CONTINUOUS INTERSTITIAL <br /> DETECTOR ❑ TESTING ❑ MONITORING " ❑4 ELECTRONIC UNE 5 AUTOMATIC PUMP MM DETECTOR ❑ SHUTDOWN [D99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 MANUAL INVENTORY ❑ 3 VADOZE ❑ 4 AUTOMATIC TANK ❑ 5 GROUND WATER �6 ANNUALTANK <br /> RECONCILIATION MONITORING GAUGING MONITORING TESTING <br /> ❑ 7 CONTINUOUS <br /> MONITORING INTERSTITIAL ❑ 6 SIR ❑ 9 ANEK GAUGANGAL ❑10 MONTHLY TANK ❑ 95 UNKNOWN ❑S OTHER <br /> TESTING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> L <br /> ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3,WAS TANK FILLED WITH YES E] No F-] <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OFFK OWNER'S NAM — P�E-RRJ'UR/Y,}AND TO THE BEST OF MY KNOWLEDGE,1S TRUE ANlD\CORRECT <br /> (PRIINTED&SIGNATURE) E _, 1 1/1 �(" �a _ /f Do ATE I <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.4 m [ p <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE " <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLIC N-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FO ^MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PULE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE IWGROUND STORAGE TANK REGULATIONS <br /> FORM B (6.95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.