COMPLIANCE INFO_1997-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 4:00:13 PM
Creation date
6/3/2020 9:50:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. E � <br /> F In-Tank Gauging/SIR Equipment: ' Check this box if tank gauging is used only for inventory " ,, <br /> ❑ Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the folloiving checklist: <br /> ❑ Yes ❑ No* Has all input wiring been inspected for proper eatry and termination;includimgtesting for ground furies? - - <br /> ❑ Yes ❑ No* Were all tank gauging probes visually iospomd for damage and residue buildup?-- — — - <br /> ❑ Yes ❑ No* Was accuracy of system product level nmdmgs tested? <br /> ❑ Yes ❑ No* "Was accuracy of system water level readings tested? <br /> El Yes ❑ No* Were all probes reinstalled properly? <br /> (3Yes ❑ No* Were all items on the equipment mane fiwanves maintanance checklist completed? <br /> *In the Section N,below,describe how and when these deficiencies were or will be correc&d. <br /> G.Line Leak Detectors(LLD): ❑ Check this box if LLDs are not installed. <br /> Com Tete the following checklist: <br /> Re lies ❑ No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performanac? <br /> ❑ N/A (Check all that apply) Simulated leak rata M g p L-. ❑0.1 94)-h; ❑02 g p h. <br /> AH Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requftwhe nts? <br /> 41 Yes ❑ No* Was the testing apparatus properly calibrated? <br /> 5KYes ❑ No* For mechanical LIDS,does the LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No* For electronic 1J-Ds,does the turbine automatically shut off if the LLD detects a leak? <br /> N/A <br /> ❑'Y'es 43 No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> N/A or disconnected? <br /> ❑ Yes ❑ No* For c is UDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions <br /> N/A or fails a test? _VM-Y -00 <br /> No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> N/A <br /> No* Were all items on the equipment manufacturer's maintenancechccklist completed? <br /> *In the Section A,below,describe how and when these deficiencies were or wM be corrected. <br /> H. Comments: <br /> Parc 3 of 3 u lien <br />
The URL can be used to link to this page
Your browser does not support the video tag.